Results 51 to 60 of about 69,772 (290)

Clinical analysis of different anesthesia methods for pulmonary infection after perioperative operation

open access: yesJournal of Infection and Public Health, 2021
The purpose is to explore the effect of different anesthesia methods on pulmonary infection after the operation. 120 patients who underwent surgery from January 2015 to August 2018 were selected in three groups: group A (n = 40), group B (n = 40), and ...
Qingqing Huang   +5 more
doaj  

Inhalation anesthesia and stress in children with oncological pathology

open access: yesZdorovʹe Rebenka, 2022
Background. Children with cancer undergo many ­operations and procedures that require anesthesia in the acute phase of the disease or during remission. An integral element of a safe anesthesia plan is the consideration of direct tumor effects.
V.I. Snisar, D.V. Myronov
doaj   +1 more source

Engineering the Hierarchical Porosity of Granular Hydrogel Scaffolds Using Porous Microgels to Improve Cell Recruitment and Tissue Integration

open access: yesAdvanced Functional Materials, Volume 35, Issue 12, March 18, 2025.
By fabricating and covalently assembling gelatin methacryloyl (GelMA) porous microgels, a new class of granular hydrogel scaffolds with hierarchical porosity is developed. These scaffolds have a significantly higher void fraction than their counterparts made up of nonporous microgels, enhancing cell recruitment and tissue integration. This research may
Alexander Kedzierski   +9 more
wiley   +1 more source

The Advantages of Low-Flow Inhalational Anesthesia

open access: yesОбщая реаниматология, 2005
The paper deals with the economical and ecological use of inhalation anesthetics in low-flow anesthesia (LFA, 1—0.5 l/ min) and high-flow anesthesia (HFA, more than 2—6 l/min).
P. Torok   +8 more
doaj   +1 more source

Effects of anesthesia on conventional and speckle tracking echocardiographic parameters in a mouse model of pressure overload [PDF]

open access: yes, 2015
Genetically‑modified mice are widely applied in cardiovascular studies as model organisms. Echocardiography is a key tool for evaluating cardiac and hemodynamic functions in mice.
Cao, Ming   +7 more
core   +1 more source

Optimizing Angiopep‐2 Density on Polymeric Nanoparticles for Enhanced Blood–Brain Barrier Penetration and Glioblastoma Targeting: Insights From In Vitro and In Vivo Experiments

open access: yesAdvanced Functional Materials, EarlyView.
The Angiopep‐2 peptide density on polymeric nanoparticles significantly impacts blood–brain barrier (BBB) penetration. This study explores this nuanced relationship using various in vitro models and in vivo assays, revealing that dynamic models better predict BBB penetration.
Weisen Zhang   +9 more
wiley   +1 more source

Depth of Anesthesia Determination by using Bispectral Index in Patients underwent Inhalation or Total Intravenous General Anesthesia

open access: yesمجله دانشکده پزشکی اصفهان, 2008
BACKGROUND: Bispectral index (BIS) is a new method for determination depth of anesthesia. In most of our operating rooms depth of anesthesia is measured according to clinical features; however, it has not enough accuracy.
Gholam Reza Kalili   +2 more
doaj  

Driving pressure during general anesthesia for open abdominal surgery (DESIGNATION) : study protocol of a randomized clinical trial [PDF]

open access: yes, 2020
Background Intraoperative driving pressure (Delta P) is associated with development of postoperative pulmonary complications (PPC). When tidal volume (V-T) is kept constant, Delta P may change according to positive end-expiratory pressure (PEEP)-induced
Aarts, Leon P. H. J.   +45 more
core   +2 more sources

A Vertically‐Stacked Optoelectronic Sensor for Localized Hemodynamics Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
This work introduces a hemodynamics monitoring sensor that features vertically stacked microLEDs and a heterogeneously integrated photodetector. The vertically stacked microLEDs enable localized measurements, and by designing the interoptode distance according to the depth of the target region, this vertically stacked optoelectronic sensor is ...
Taeyeon Lee   +9 more
wiley   +1 more source

Home Cage Compared with Induction Chamber for Euthanasia of Laboratory Rats [PDF]

open access: yes, 2018
This study compared behavioral and physiologic changes in Sprague-Dawley and Brown Norway rats that were euthanizedby using a 30% volume displacement rate of CO2 in either their home cage or an induction chamber; rats euthanized in thehome cage were ...
Hickman, Debra L.
core   +1 more source

Home - About - Disclaimer - Privacy