Results 141 to 150 of about 413,108 (297)

Geometry‐Related Technical Complications After LVAD Implantation: Impact on Device Dysfunction and Clinical Outcomes

open access: yesArtificial Organs, EarlyView.
Preventable geometric failure modes, such as outflow graft kinking and inflow malposition, frequently cause HeartMate 3 dysfunction. This study identifies these complications as key drivers of device‐related morbidity, highlighting the importance of optimized surgical positioning to ensure long‐term device performance and improved clinical outcomes ...
Ali Saad Merzah   +17 more
wiley   +1 more source

Heart and Thoracic Aorta (Labeled)

open access: yes
Heart.
Royal College of Surgeons of Ireland (RCSI)
core   +1 more source

Suprahepatic inferior vena cava cannulation

open access: yes, 1999
Inadequate venous drainage may represent a major problem in operations on the descending thoracic aorta performed with the aid of cardiopulmonary bypass.
Massetti, Massimo
core  

Monitoring Mitochondrial Function With High‐Resolution Respirometry During Ex‐Situ Heart Perfusion

open access: yesArtificial Organs, EarlyView.
Normothermic ESHP preserves mitochondrial respiratory function over 6 h in a porcine model (n = 6): OXPHOS capacities across NADH‐, fatty‐acid‐, and succinate‐linked pathways remain stable, with reduced cytochrome‐c control efficiency indicating improved outer‐membrane integrity. HRR provides a rapid, actionable readout for organ assessment.
Lukas Stastny   +12 more
wiley   +1 more source

The Thoracic Aorta in Turkish Sheepherd Dog

open access: yes, 2000
This study was carried out to investigate the arterial vascularization of the thoracic aorta in Turkish sheepherd dog. As a material, fourteen adult dogs were used.
Gezici, Memduh, Dursun, Nejdet
core  

Efficacy of Antimicrobial Silver‐Plated Dressings Compared to Usual Care in Preventing Left Ventricular Assist Device Driveline Infections

open access: yesArtificial Organs, EarlyView.
Integrating silver‐plated wound dressings into DLES care presents a safe and effective strategy for DLI prevention. Key findings include a 100% infection‐free rate in the Silverlon group, no NPWT and hospital readmission in the Silverlon group, and no severe DESTINE stages (3, 4) in the Silverlon group.
Barbara Veiter   +9 more
wiley   +1 more source

Mini-sternotomy as a life-saving access for thoracic endovascular aortic repair in the absence of peripheral options. [PDF]

open access: yesJ Thorac Dis
Buczkowski P   +11 more
europepmc   +1 more source

Formononetin induces vasorelaxation in rat thoracic aorta via regulation of the PI3K/PTEN/Akt signaling pathway

open access: yes, 2018
Teng Li, Yuanyuan Zhong, Tao Tang, Jiekun Luo, Hanjin Cui, Rong Fan, Yang Wang, Dongsheng Wang Laboratory of Ethnopharmacology, Institute of Integrative Medicine, Xiangya Hospital, Central South University, Changsha 410008, China Background: Formononetin
Li T   +7 more
core  

SURGELLA: A Scoping Review of Impella‐Assisted Hemodynamic Support in High‐Risk Non‐Cardiac Surgery

open access: yesArtificial Organs, EarlyView.
In selected patients with severe LV dysfunction, Impella‐supported non‐cardiac surgery may provide a temporary hemodynamic bridge to otherwise prohibitive procedures. Published evidence remains limited to a small number of highly selected cases, supporting technical feasibility rather than comparative benefit or generalizable safety.
Hussein Elghazaly   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy