Results 231 to 240 of about 264,693 (308)

Hemocompatibility Outcomes After Aspirin Withdrawal in Long‐Term HeartMate 3 Left Ventricular Assist Device Patients on Vitamin K Antagonists

open access: yesArtificial Organs, EarlyView.
Aspirin discontinuation in long‐term, stable Heart Mate 3 LVAD patients maintained on Vitamin K antagonists did not increase hemocompatibility‐related adverse events. These findings support the safety of simplified antithrombotic therapy and extend randomized evidence for aspirin avoidance to the long‐term management of Heart Mate 3 recipients ...
Melanie Arnreiter   +8 more
wiley   +1 more source

Outcomes in Patients Requiring VENO‐Venous Extracorporeal Membrane Oxygenation After Cardiac Surgery: An Analysis From the PELS‐1 Study

open access: yesArtificial Organs, EarlyView.
We report an insight from the PELS‐1– a multicentre, international registry focusing on postocardiotomy extracorporeal support use between 2000 and 2020. We focused on 24/2163 (1.1%) patients requiring V‐V ECMO after cardiac surgery. Mortality was high, with 21.7% of patients discharged alive and an overall 1‐year survival probability of 12.5 ...
Pasquale Nardelli   +39 more
wiley   +1 more source

Validation of Aortic Blood Flow Simulations During Extracorporeal Circulation Using Phase Contrast Magnetic Resonance Imaging

open access: yesArtificial Organs, EarlyView.
This is the first study assessing in vivo blood flow profiles during extracorporeal circulation (ECC) scenarios. Magnetic resonance imaging data served for the calibration of computational fluid dynamics algorithms, enabling accurate replication of the hemodynamic conditions.
Anna Kathrin Assmann   +9 more
wiley   +1 more source

Comparison of Intraoperative Doppler Flow Measurements and Algorithmic Flow Estimations in Patients Undergoing Durable Left Ventricular Assist Device Implantation

open access: yesArtificial Organs, EarlyView.
Direct intraoperative HeartMate 3 LVAD flow measurements using an ultrasonic probe revealed consistently higher values by approximately 0.5 L/min compared to device‐estimated flows. This discrepancy remained stable across pump speed settings, highlighting the importance of distinguishing measured from estimated flow in HeartMate 3 patients.
Gaik Nersesian   +13 more
wiley   +1 more source

Identification of Autologous Tissue Sources and Optimization of a Treatment Method for Intraoperative Manufacturing of Heart Valve Constructs

open access: yesArtificial Organs, EarlyView.
The use of autologous connective tissue, such as pericardium or peritoneum, combined with controlled tissue treatment, has the potential to result in a more durable heart valve prosthesis than current commercial prostheses. ABSTRACT Introduction Valvular heart disease remains a leading cause of morbidity and mortality. Current biological and mechanical
Marvin Steitz   +17 more
wiley   +1 more source

The first case of Reel Syndrome in a dog after pacemaker implantation: A case report

open access: yesAustralian Veterinary Journal, EarlyView.
Reel Syndrome is a rare complication of permanent pacemaker implantation, characterised by the rotation of the device around its transverse axis, which causes the lead to coil around the generator and displacement, leading to pacing dysfunction. This report presents the first documented case of Reel Syndrome in a dog.
Z Wojtczak   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy