Results 91 to 100 of about 149 (149)

The impact of frailty syndrome on skeletal muscle histology: preventive effects of exercise

open access: yesFEBS Open Bio, EarlyView.
Frailty syndrome exacerbates skeletal muscle degeneration via increased ECM deposition and myofiber loss. This study, using a murine model, demonstrates that endurance exercise attenuates these histopathological alterations, preserving muscle integrity. Findings support exercise as a viable strategy to counteract frailty‐induced musculoskeletal decline
Fujue Ji   +3 more
wiley   +1 more source

An approach for coherent periodogram averaging of tilt‐series data for improved contrast transfer function estimation

open access: yesFEBS Open Bio, EarlyView.
The contrast transfer function (CTF) is an imaging aberration that is a major resolution‐limiting factor in cryo‐electron microscopy (cryo‐EM). Precise CTF estimation is key to overcoming this limitation, but is particularly challenging in cryo‐electron tomography (cryo‐ET) data. Here, we present an approach for using geometric information to assist in
Sagar Khavnekar, William Wan
wiley   +1 more source

Development of 4T1 breast cancer mouse model system for preclinical carbonic anhydrase IX studies

open access: yesFEBS Open Bio, EarlyView.
Carbonic anhydrase IX (CAIX) is a well‐recognised therapeutic target and prognostic biomarker in cancer. We developed and characterised a robust murine breast cancer model system that is suitable for CAIX studies in vitro and in vivo—it comprises both CAIX‐positive and CAIX‐negative controls and provides a solid platform for the comprehensive ...
Zane Kalniņa   +13 more
wiley   +1 more source

GDP‐fucose transporter SLC35C1: a potential regulatory role in cytosolic GDP‐fucose and fucosylated glycan synthesis

open access: yesFEBS Open Bio, EarlyView.
The inactivation of SLC35C1 (GDP‐fucose transporter) and enzymes involved in GDP‐fucose biosynthesis was studied. Fucose supplementation increases the level of GDP‐fucose to abnormal, millimolar values in the absence of the TSTA3 protein and SLC35C1 in contrast to the GMDS/SLC35C1 double mutant.
Edyta Skurska, Mariusz Olczak
wiley   +1 more source

Approximating the best approximation operator

open access: yesJournal of Approximation Theory, 1972
openaire   +2 more sources

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós   +11 more
wiley   +1 more source

From 2D to 3D gamma passing rate tolerance and action limits for patient‐specific quality assurance in volumetric‐modulated arc therapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Volumetric modulated arc therapy (VMAT) requires an accurate patient‐specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ‐index and the two‐dimensional gamma passing rate (2D %GP). A three‐dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose ...
Christos Zarros   +6 more
wiley   +1 more source

Modelling of a double‐scattering proton therapy nozzle using the FLUKA Monte Carlo code and analysis of linear energy transfer in patients treated for prostate cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The dose‐averaged linear energy transfer (LETD) in proton therapy (PT) has in pre‐clinical studies been linked to the relative biological effectiveness (RBE) of protons. Until recently, the most common PT delivery method in prostate cancer has been double‐scattered PT, with LETD only available through dedicated Monte Carlo (MC ...
Rasmus Klitgaard   +7 more
wiley   +1 more source

A review of artificial intelligence in brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen   +4 more
wiley   +1 more source

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy