Results 71 to 80 of about 381,921 (325)
Analisis Pengaruh Diameter Dan Panjang Elektroda Pentanahan Arester Terhadap Perlindungan Tegangan Lebih [PDF]
Untuk melindungi peralatan listrik tersebut perlu adanya suatu perlindungan maksimal sehingga gangguan dapat diminimalisir. Diperlukan adanya pemasangan kawat atau elektroda yang terhubung langsung ke tanah untuk pengamanan peralatan tersebut ...
Najib, Syaifuddin
core +1 more source
CDK11 inhibition stabilises the tumour suppressor p53 and triggers the production of an alternative p21WAF1 splice variant p21L, through the inactivation of the spliceosomal protein SF3B1. Unlike the canonical p21WAF1 protein, p21L is localised in the cytoplasm and has reduced cell cycle‐blocking activity.
Radovan Krejcir +12 more
wiley +1 more source
Condition Assessment of Metal Oxide Surge Arrester Based on Multi-Layer SVM Classifier
This paper introduces the indicators for surge arrester condition assessment based on the leakage current analysis. Maximum amplitude of fundamental harmonic of the resistive leakage current, maximum amplitude of third harmonic of the resistive leakage ...
M Khodsuz, M Mirzaie
doaj
Comparison of transformer modeling on riser pole arresters behavior during switching transients
Arresters are widely used in power systems to protect other equipment against overvoltages. However, in some conditions, they can’t operate successfully.
Abbaszadeh Amir +2 more
doaj +1 more source
Model Arrester SiC Menggunakan Model Arrester ZnO IEEE WG 3.4.11 [PDF]
Arrester model is needed to analyse the insulation coordination in power system. The model should give a suitable respon for varying transient fault. In this paper, we conduct simulation that modified from IEEE WG 3.4.11 model.
Haryono, T. (T) +2 more
core
Clinical trials on PARP inhibitors in urothelial carcinoma (UC) showed limited efficacy and a lack of predictive biomarkers. We propose SLFN5, SLFN11, and OAS1 as UC‐specific response predictors. We suggest Talazoparib as the better PARP inhibitor for UC than Olaparib.
Jutta Schmitz +15 more
wiley +1 more source
A Simplified Lightning Model for Metal Oxide Surge Arrester [PDF]
Lightning strike has been one of the major factors that lead to failure of electrical power systems. In recent years, metal oxide surge arrester has been widely used and it is now an essential item in the insulation coordination for power systems based ...
Mardira, K. P., Saha, T.K.
core
On the placement of line arrester on underbuilt overhead distribution line [PDF]
Lightning performance of distribution line is an important issue in the countries with high lightning density such as Malaysia. Many studies have been carried out to investigate the lightning performance and thus protect the overhead line from this ...
Ab Kadir, Mohd Zainal Abidin +2 more
core +1 more source
Dual targeting of RET and SRC synergizes in RET fusion‐positive cancer cells
Despite the strong activity of selective RET tyrosine kinase inhibitors (TKIs), resistance of RET fusion‐positive (RET+) lung cancer and thyroid cancer frequently occurs and is mainly driven by RET‐independent bypass mechanisms. Son et al. show that SRC TKIs significantly inhibit PAK and AKT survival signaling and enhance the efficacy of RET TKIs in ...
Juhyeon Son +13 more
wiley +1 more source
Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management [PDF]
Peer ...
Jovcic, Dragan +3 more
core +1 more source

