Results 21 to 30 of about 438,424 (336)
Modelling and validation of metal oxide surge arrester for very fast transients
Metal oxide surge arrester models that are currently on rounds suffer from certain deficiencies and as a consequence, they are not in position to portray accurately the arrester residual voltages.
Kannadasan Raju, Valsalal Prasad
doaj +1 more source
Development of a Low-Energy Mobile Current Waveform Impulse Generator for Application in Low Voltage Surge Arresters [PDF]
Surge arresters are at the forefront of protection against voltage surges. The loss of the protective effect of surge arresters imposes accidents and unplanned shutdowns on the power system.
Tiago Goncalves Zacarias +9 more
doaj +1 more source
Study on Flow Performance of Airboard Flame Arresters
In our country, as the airworthiness certification and aviation technology are lagging far behind, the development of domestic airborne flame arrester has just been included into the agenda. Hence, based on the analysis of the reason of the pressure drop
Liu Minghui +4 more
doaj +1 more source
In zinc oxide (ZnO) surge arresters, leakage current usually flows across the arrester under normal operating condition. Leakage current is one of the factors which contribute towards degradation of surge arresters and therefore, it is very important to ...
N. A. A. Latiff +3 more
semanticscholar +1 more source
Condition monitoring of zinc oxide surge arresters [PDF]
Over voltages in power system may occur due to lightning, fault or switching operation. These overvoltages could reach dangerous amplitudes for power system apparatus.
Nouruddeen Bashir +8 more
core +1 more source
Modelling of Metal Oxide Surge Arresters in Simulation Software DYNAST
This paper describes the possibilities for mathematical modelling of gap-less surge arresters in the simulation software DYNAST. This tool does not belong to standard modelling softwares in the field of electric power engineering. However, it may provide
Vladislav Síťař, Jan Veleba
semanticscholar +1 more source
Experimental study on premixed flame acceleration in closed pipe [PDF]
An experimental study has been carried out to investigate the flame acceleration in closed pipe. A horizontal steel pipe, with 2 m long and 0.1 m diameter, giving length to diameter (L/D) ratio of 20 was used in this project.
M. Kasmani, R., Mat Kiah, M. H.
core +1 more source
PERFORMANCE OF PARALLEL SURGE ARRESTERS [PDF]
The operation of parallel surge arresters can improve energy absorption capability if the arresters are similar and are installed close to each other.
Griffiths, H., Osborne, M., Haddad, A.
core +1 more source
This simulation study presents the effect of lightning strikes on the performance of arresters at 150 kV overhead lines. Lightning strikes have several parameters that affect the performance of line arresters (LA), namely lightning charge, and impulse ...
Fri Murdiya +4 more
doaj +1 more source
As a result of lightning strikes, pollution, and ice, overhead distribution wires might be short-circuited and trip. As a result, researchers have developed a new lightning protection composite insulator.
Jiazheng Lu +4 more
doaj +1 more source

