Results 91 to 100 of about 1,150,578 (208)

Measurement of brain perfusion in newborns: Pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL)

open access: yesNeuroImage: Clinical, 2014
Background: Arterial spin labeling (ASL) perfusion-weighted imaging (PWI) by magnetic resonance imaging (MRI) has been shown to be useful for identifying asphyxiated newborns at risk of developing brain injury, whether or not therapeutic hypothermia was ...
Elodie Boudes   +6 more
doaj   +1 more source

Inter‐Shot Motion Correction of Segmented 3D‐GRASE ASL Perfusion Imaging With Self‐Navigation and CAIPI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1557-1571, October 2026.
ABSTRACT Purpose Segmented 3D Gradient and Spin Echo (GRASE) is commonly used in Arterial Spin Labeling (ASL) perfusion imaging. However, it is vulnerable to inter‐shot motion, leading to subtraction errors that cannot be corrected. We developed a retrospective self‐navigated inter‐shot motion correction method for segmented 3D‐GRASE ASL imaging with ...
Minhao Hu   +5 more
wiley   +1 more source

Arterial spin labeling perfusion MRI: reproducibility & clinical applications [PDF]

open access: yes, 2012
Arterial Spin Labeling (ASL) is een relatief nieuwe MRI-techniek die de doorbloeding van de hersenen in beeld brengt zonder te hoeven snijden. Anders dan bij andere technieken die de doorbloeding in beeld kunnen brengen, is er bij ASL geen contrastmiddel
Gevers, J.K.M.
core   +4 more sources

Role of contrast-free MR-perfusion in the diagnosis of potential epileptogenic foci in children with focal epilepsia

open access: yesЭпилепсия и пароксизмальные состояния, 2018
ASL (Arterial Spin Labeling) – a novel modality of MR angiography – is based on radio-frequency labeling of aqueous protons in the arterial blood; the method is used to monitor blood supply to  organs, including the brain.
M. V. Polyanskaya   +6 more
doaj   +1 more source

Commentary on Ferumoxytol and Beyond: Navigating the Shift Away From GBCAs in Neuro‐Oncology

open access: yes
Journal of Magnetic Resonance Imaging, EarlyView.
Vera C. Keil, Yelda Özsunar
wiley   +1 more source

Multiple‐TE Based Blood–Brain‐Barrier Water Exchange Time Measurement Using a TE‐Resolved 3D TSE Stack‐Of‐Spirals Readout

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1629-1644, October 2026.
ABSTRACT Purpose To develop a slice‐wise blurring‐free and densely sampled TE‐resolved multiple‐TE (mTE) ASL sequence (TASL) for measuring blood–brain barrier (BBB) water exchange time. Methods A 3D TSE spiral‐readout pCASL sequence was modified to enable TE‐resolved acquisition.
Bo Li   +11 more
wiley   +1 more source

Arterial spin labeling perfusion-weighted MRI for long-term follow-up of a cerebral arteriovenous malformation after stereotactic radiosurgery

open access: yesActa Radiologica Short Reports, 2014
We present a longitudinal series of arterial spin-labeling magnetic resonance imaging (ASL-MRI) in a patient with cerebral arteriovenous malformations (AVMs) treated by stereotactic radiosurgery (SRS). Pretreatment ASL-MRI showed high signal intensity in
Kazuhiro Shimizu   +6 more
doaj   +1 more source

Ictal and Interictal Arterial Spin Labelling (ASL) in Hemimegalencephaly

open access: yesAnnals of Indian Academy of Neurology, 2021
Bina Thakor   +3 more
openaire   +3 more sources

Pseudocontinuous Arterial Spin Labeling Perfusion Magnetic Resonance Imaging-a Normative Study of Reproducibility in the Human Brain

open access: yes, 2012
Pseudocontinuous arterial spin labeling (PCASL), a newly proposed perfusion magnetic resonance imaging (MRI) technique, has the potential of providing a better balance between labeling efficiency and signal-to- noise ratio than conventional ASL methods ...
吳文超;江淑芬;楊舜仲;連淑華   +1 more
core  

Denoising of ASL Data Using Deep Learning Priors Generated From Distribution Remapping

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1972-1982, October 2026.
ABSTRACT Purpose To develop an effective deep learning (DL)–based method to denoise arterial spin labeling (ASL) data. Methods Conventional DL–based ASL denoising methods often suffer from overfitting and poor generalization when training data are limited.
Ziyang Xu   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy