Practical calculation of asymmetric short circuit current of DFIG connected to distribution network [PDF]
In view of the existing complex analytic calculations of DFIG short-circuit current are hardly applied in engineering projects, a practical calculation of asymmetric short-circuit current of DFIG is proposed.
Fu Pengwu +4 more
doaj +2 more sources
The three-phase three-wire stand-alone inverter is required to have short-circuit fault ridethrough ability to achieve continuity of power supply. Generally the inverter works in current-controlled mode in symmetric short-circuit conditions, but voltage ...
Jian He +3 more
doaj +3 more sources
Research on the Short-Circuit Characteristics of Trench-Type SiC Power MOSFETs Under Single and Repetitive Pulse Strikes [PDF]
This paper investigates the short-circuit characteristics of 1.2 kV symmetrical and asymmetrical trench-gate SiC MOSFETs. Based on the self-designed short-circuit test platform, single and repetitive short-circuit tests were carried out to characterize ...
Li Liu +4 more
doaj +2 more sources
The early inter-turn short-circuit fault of field winding (ISFF) occurs between adjacent strands in a single rotor slot, which is a significant safety hazard in the transient operation of the large-capacity synchronous condenser.
Weihao Wang +3 more
doaj +3 more sources
Peptide Sequence Programmed Piezoelectric Response by Supramolecular SelfâAssembly [PDF]
Piezoelectricity has attracted significant attention for its ability to convert mechanical energy into electricity, especially when biological molecules are incorporated into materials.
Xuejiao Yang +6 more
doaj +2 more sources
Increasing the Sensitivity of the Digital Relay Protection Against Turn-to-turn Short Circuits And Asymmetries In Wind Power Generators [PDF]
The paper describes the implementation of neural networks for increasing the sensitivity of the digital relay protection against turn-to turn short circuits in the stator winding and asymmetric modes in wind power generators.
Nedelchev Nedelcho, Matsankov Misho
doaj +1 more source
Asymmetric short-circuit fault breaking test T100a is an important test item of High-voltage AC Circuit-breakers. In non-effectively earthed neutral system the first pole to clear factor is 1.5 and the transient recovery voltage (TRV) has two or four ...
HE Ninghui +5 more
doaj +1 more source
Overvoltage in the free phase of the stator winding in case of asymmetric short circuit implicit pole synchronous generator biaxial excitation [PDF]
Reviewed and analyzed issues associated with overvoltage in the free phase winding of the stator with asymmetric short-circuit implicitly pole synchronous generator biaxial excitation, and compared the results of experimental measurements of the phase ...
Pirmatov Nurali, Toshev Sherzod
doaj +1 more source
With the rapid growth of renewable energy sources, single-phase rooftop photovoltaic inverters connected to the distribution network have received widespread applications in recent years.
Yuming Liao +3 more
doaj +1 more source
This paper introduces a novel approach for detecting inter-turn short-circuit faults in rotor windings using wavelet transformation and empirical mode decomposition.
Attiq Ur Rehman +6 more
doaj +1 more source