Results 31 to 40 of about 586 (166)
基于ATP-EMTP仿真软件的输电线路雷击跳闸率多因素对比分析研究
通过电磁暂态仿真程序ATP-EMTP,建立了110 kV输电线路的雷击分析模型,主要包括:雷电流模型、杆塔模型、绝缘子串闪络模型等,该模型可以真实地反映雷电流在杆塔上的传播过程。然后分别利用规程法和ATP仿真法进行了计算与分析,得到线路在不同条件下的跳闸率;分析了杆塔高度、冲击接地电阻以及线路绝缘水平等因素对雷击跳闸率的影响。结果表明:在同等情况下,ATP-EMTP仿真计算的反击跳闸率略高于规程法的计算值;随着杆塔高度的降低、杆塔冲击接地电阻的减小、绝缘强度的增强,反击跳闸率减小。
肖安南 +6 more
doaj
This paper primarily investigates the patterns of overvoltage changes during an interruption of oil‐immersed iron‐core reactors by circuit breakers and their distribution along the axial windings of the reactor, which optimises the winding structure. ABSTRACT This paper primarily investigates the patterns of overvoltage changes during an interruption ...
Hongyan Nie +4 more
wiley +1 more source
Analytical Frameworks and Theories of Electric Power in Non‐Linear Circuits
Based on the challenges of distorted currents and non‐linear components in modern power grids, this article reviews seminal electrical power theories that seek to generalize the traditional definitions of active, reactive, and apparent power. It provides a detailed analysis of their mathematical foundations, practical implementation, and validity.
Rafael Escudero, Luis Ibarra
wiley +1 more source
对避雷器内部局部放电的定位方法进行研究,提出了一种有效的针对避雷器及其类似设备内部缺陷定位的极性定位法,并通过EMTP/ATP仿真技术及现场试验验证,验证了该方法的正确性和可行性,具有一定的工程实践意义。
邱太洪 +4 more
doaj
Ultra-Fast Busbar Protection by Applying TT-transform on Superimposed Current Signals [PDF]
In this paper a new method for busbar protection is presented. In this method high frequency components generated by faults in current signals at the outputs of current transformers of substations are extracted by applying TT transform and then the ...
Mahmood Lashgari, S. Mohammad Shahrtash
doaj +1 more source
A New Hybrid Method for Adaptive and Online Faulted Phase Selection in Power Transmission Lines
This study proposes a new hybrid method online faulted phase selection for the power transmission lines using local measurements, which is adaptive and independent of various fault detection times. The method is suitable for online faulted phase selection in digital relays with limited computational resources.
Ali Kaffashbashi, Yaser Damchi
wiley +1 more source
Engineering guidelines for optimal NGLA configuration in 750 kV HVAC systems are established, offering an economical and reliable alternative to traditional breaker closing resistors for switching overvoltage suppression, with both theoretical and engineering application values.
Tongwei Guo +6 more
wiley +1 more source
Journal of Magnetic Resonance Imaging, Volume 63, Issue 4, Page 1204-1207, April 2026.
Stefano Mandija +17 more
wiley +1 more source
This article presents a practical parameter‐extraction method for a lumped‐element three‐phase transformer model based on primary‐current data from a finite‐element simulation. In particular, the no‐load and short‐circuit cases are used to extract the leakage parameters, also capturing load cases.
Alexander Sauseng +3 more
wiley +1 more source
采用ATP-EMTP软件搭建某实际线路模型,通过规程计算与仿真计算,对比分析3种雷击方式下的耐雷水平,研究哪种情况对线路的危害最大。针对雷击塔顶这种方式下,仿真分析其变量对耐雷水平的影响程度。并分析规程计算与仿真计算耐雷水平时产生误差的原因。认为:在对线路采取防雷措施时应特别考虑雷击塔顶这种情况并首先应将各基杆塔的接地电阻降至标准值以下。
陈冬, 刘建华, 贾晨曦
doaj