Results 21 to 30 of about 193,804 (193)
Optimization of dynamic MOSA model parameters using ATP/EMTP software tool [PDF]
This paper demonstrates the procedure for estimating parameters of a dynamic metal-oxide surge arrester model by using a genetic algorithm, implemented in ATP/EMTP graphic preprocessor (ATPDraw) optimization module.
Jasika Ranko +3 more
doaj +1 more source
NUMERICAL ANALYSIS OF ELECTRICAL CIRCUITS BY ATP-EMTP PROGRAM PACKAGE
U ovom završnom radu obrađena je problematika numeričke analize električnih strujnih krugova pomoću programskog paketa ATP-EMTP. Numeričko modeliranje izmjeničnih strujnih krugova provodi se na isti način kao i numeričko modeliranje istosmjernih strujnih
Leskur, Ante
core +2 more sources
This paper discusses the step and touch voltages, based on body resistance, in a grounding grid after a lightning strike at a 434-/21-kV substation. To ensure grounding grid safety, the maximum step and touch voltage should not exceed the safety criteria
Saeid Gholami Farkoush +5 more
doaj +1 more source
[Introduction] The safe and stable operation of UHV transmission lines is essential to the safety of power grids. When the new substation deconstructs the original long line in the power grid planning and construction, the following problems, such as the
ZHENG Xing, CHEN Yipeng, QI Donghui
doaj +1 more source
This paper proposes three techniques for locating lightning strikes in a 115 kV transmission system over 88.5 km, based on the arrival time of a transient wave obtained from a discrete wavelet transform (DWT).
Pathomthat Chiradeja +1 more
doaj +1 more source
Simulation of electromagnetic influence of railway overhead contact system on disconnected transmission lines by the ATP-EMTP programme [PDF]
This paper is devoted to experimental and calculating research of induced voltage on disconnected transmission lines caused by the influence of AC railway overhead contact system.
Zalesova O. V.
doaj +1 more source
Overview of Transient Simulations of Grounding Systems under Surge Conditions
The present paper gives an overview of modelling methods of standard grounding systems under surge conditions, using the non-uniform transmission line approach.
Tomasz Kisielewicz, Milton Cuenca
doaj +1 more source
Research on suppression measures of ferromagnetic resonance based on ATP-EMTP [PDF]
Abstract Aiming at the electromagnetic transformer of a 35kV substation in a certain area, a simulation model of ferromagnetic resonance based on ATP-EMTP software was established. Several methods of suppressing ferromagnetic resonance overvoltage were analyzed, and it was found that the harmonic elimination device could not completely ...
Weili Wu, Tianming Zhang
openaire +1 more source
This paper deals with an analysis of impedance-differential protection algorithm applied to locate faults on a double-circuit transmission line. In particular, the study of fault location accuracy for the case of using the relation between currents for ...
Ю. Герлендер +2 more
doaj +1 more source
Research on Comprehensive Closing Protection for Capacitor based on ATP/EMTP [PDF]
Aiming at solving the problem of dash current and over voltage of parallel reactive compensation capacitor group in power system ,this paper research on the phase control synchronous switch and the current-limiting reactor .With the of Huangti system, which involves both of the protection tools, Simulation result demonstrates that dash current and the ...
Hao Zhou, He Liu
openaire +1 more source