Results 41 to 50 of about 149,836 (181)

Use of the EMTP-ATP Software to Develop a Dynamic Model of the Technological Centre

open access: yesAdvances in Electrical and Electronic Engineering, 2016
This paper deals with analysis of power generating units installed within the technological centre. To be able to analyse behaviour of such a complex system with accumulation, the dynamic model of the technology was created using the EMTP-ATP software ...
Tomas Mozdren   +3 more
doaj   +1 more source

The distribution of ATP within tomato (Lycopersicon esculentum Mill.) embryos correlates with germination whee as total ATP concentration does not

open access: yes, 2002
The distribution of ATP in tomato seeds was visualized by monitoring the luminescence of frozen sections on top of a gel containing all the components of the luciferase reaction, but excluding ATP.
Joosen, R.V.L.   +2 more
core   +1 more source

超高压变电站雷电过电压现场实测与仿真计算

open access: yesDianci bileiqi, 2008
简述了电力系统过电压问题的研究方法:TNA具有直观性,实测具有真实性,仿真计算具有灵活性。为研究某超高压变电站雷电过电压与绝缘配合问题,用低压冲击波进行了时间比例尺、阻抗比例尺均为1的现场试验,且用ATP-EMTP仿真计算了设备上的雷电侵入波过电压。试验结果表明,一线一变、一线两变两种运行方式下,降压实测与ATP-EMTP仿真计算结果基本一致,说明将实测与计算结合起来是一种分析此类问题很好的方法。
陈敏   +7 more
doaj  

MODELO DE TRANSFORMADORES EN SATURACIÓN UTILIZANDO FUNCIONES DE CÁLCULO DE PARÁMETROS EN EMTP-RV

open access: yesIngeniería, 2014
La representación del fenómeno de saturación de un transformador es imprescindible en los estudios de transitorios electromagnéticos, principalmente porque debe representar con exactitud la sobrexcitación del transformador durante su energización, además
Leonardo Montealegre Lobo
doaj   +1 more source

Modelación y Validación en ATP de los Cables Subterráneo y Submarino del Sistema de Subtransmisión Baltra - Santa Cruz

open access: yesRevista Técnica Energía, 2017
En este trabajo, basados en el estado del arte, se presentan los criterios usados para la modelación y validación de los cables tripolares subterráneo y submarino del sistema de subtransmisión Baltra– Santa Cruz. Para modelar los cables en rutinas Cable
L. Dután
doaj   +1 more source

Travelling-wave based fault distance estimation for series compensated transmission lines using ATP-EMTP.

open access: yes, 2015
In this paper, a traveling wave is used for determining fault distance of series compensated transmission lines using frequencies of fault generated and voltage ...
Akmaz, Düzgün, Mamiş, Mehmet Salih
core  

基于ATP-EMTP的耐雷水平研究

open access: yesDianci bileiqi, 2011
采用ATP-EMTP软件搭建某实际线路模型,通过规程计算与仿真计算,对比分析3种雷击方式下的耐雷水平,研究哪种情况对线路的危害最大。针对雷击塔顶这种方式下,仿真分析其变量对耐雷水平的影响程度。并分析规程计算与仿真计算耐雷水平时产生误差的原因。认为:在对线路采取防雷措施时应特别考虑雷击塔顶这种情况并首先应将各基杆塔的接地电阻降至标准值以下。
陈冬, 刘建华, 贾晨曦
doaj  

No-load energization of a 380 kV underground cable: temporary overvoltages

open access: yes, 2006
Dresda (Germania),EEUG - European EMTP-ATP Users Group Meeting ...
GATTA, Fabio Massimo   +2 more
core  

An ATP-EMTP-Based Model for Analysis of Shielding Properties of Ferromagnetic Cable Sheaths

open access: yesIEEE Transactions on Power Delivery, 2005
Ferromagnetic materials, such as steel, are used for shielding of power and telecommunication cables. These shields often provide path for currents during faults or lightning and are important for the integrity and safety of electrical systems and devices.
Popov, M. (author)   +3 more
openaire   +4 more sources

Studi Pemasangan Damping Reaktor untuk Mengatasi Feroresonansi pada Incoming 20 kV GIS Tandes

open access: yesJurnal Teknik ITS, 2015
Pada studi ini, dilakukan simulasi pemasangan damping reaktor sebagai salah satu teknik mitigasi feroresonansi dengan menggunakan ATP Draw. Damping reaktor sebagai teknik mitigasi feroresonansi menggunakan elemen resistor yang dipasang di sisi primer ...
Satria Seventino Simamora   +2 more
doaj  

Home - About - Disclaimer - Privacy