Results 41 to 50 of about 586 (166)
A large number of electromagnetic transient studies have been analyzed for finding the overvoltage behavior of power system. A grounding grid of power system is so important for reducing the effect of overvoltage phenomena during a short-circuit event ...
Saeid Gholami Farkoush +7 more
doaj +1 more source
This study proposes a distributed control system using a multiagent system (MAS) to regulate the DC bus voltage in a grid‐connected microgrid through a co‐simulation environment. The framework integrates MAS (Python), TCP/IP communication and standard simulation tools (PLECS, PSIM and RTDS), enabling coordinated operation of PV arrays, battery storage ...
Daniel Leocádio Fernandes +2 more
wiley +1 more source
国内煤矿输电线路防雷技术众多,从目前使用情况看,效果不是很好。主要原因是雷电活动的随机性,加上煤矿所处环境的复杂性,很难确定雷击故障的类型,造成防雷措施针对性不够强[1]。介绍了一种基于ATP-EMTP的线路避雷器的仿真,建立的某煤矿的线路防雷模型,仿真并验证了避雷器安装原则,对合理、经济使用线路避雷器这一防雷措施具有建设性的意义。
刘建华, 姚建国, 李慧敏
doaj
DFIG Low‐Voltage Ride‐Through in Weak Grids: Rotor Overcurrent, PLL Effects, and Crowbar Boundaries
Doubly‐fed induction generator (DFIG) wind turbines can experience severe rotor overcurrent during low‐voltage ride‐through (LVRT) in weak grids because voltage magnitude and angle disturbances interact with converter and phase‐locked‐loop (PLL) dynamics.
Abdullah Alassaf, Ibrahim Alsaleh
wiley +1 more source
MMC HVDC Controls for Damping Subsynchronous Interactions With LCC HVDC and Thermal Generator
This paper develops a subsynchronous damping controller (SSDC) on modular multilevel converter (MMC) HVDC with the aim of mitigating three‐way torsional interactions between a line commutated converter (LCC) HVDC, MMC HVDC and a nuclear generator. The test case is based on the French IFA2000 2 GW LCC HVDC and the new 1 GW MMC Eleclink, interacting with
Stefan Kovacevic +4 more
wiley +1 more source
An ATP-EMTP-Based Model for Analysis of Shielding Properties of Ferromagnetic Cable Sheaths
Ferromagnetic materials, such as steel, are used for shielding of power and telecommunication cables. These shields often provide path for currents during faults or lightning and are important for the integrity and safety of electrical systems and devices.
Popov, M. (author) +3 more
openaire +4 more sources
Algoritmos para localización de fallas en líneas de transmisión, análisis para el caso colombiano
Se analizan cuatro algoritmos localizadores de fallas en líneas de transmisión, aplicados en el sistema de transmisión nacional colombiano. Se determina cual es más preciso y eficiente. Finalmente, se verifican por medio de simulaciones en EMTP/ATP, y
Gina M. Idárraga Ospina +2 more
doaj
Journal of Magnetic Resonance Imaging, Volume 63, Issue 1, Page 279-281, January 2026.
Stefano Mandija +10 more
wiley +1 more source
Analysis of voltage sag compensation in distribution systems using a multilevel DSTATCOM in ATP/EMTP
Los hundimientos de tensión (sags) son perturbaciones de calida d de potencia comunes en los sistemas eléctricos. Estos pueden causar daños en equipos sensibles y la interrupción de procesos.
Herbert Enrique Rojas-Cubides +2 more
doaj
Lightning-induced backflashovers pose significant risks to high-voltage transmission systems, particularly in high lightning activity regions. Conventional backflashover rate (BFR) estimation methods rely on simplified empirical formulas that lack ...
André T. Lobato +4 more
doaj +1 more source