Results 11 to 20 of about 175,376 (264)
Airway compression is a common complication of TB lymphadenopathy in children, and the diagnostic workup of patients with suspected tracheal or bronchial stenoses includes bronchoscopy and CT (computed tomography).2 This process affords the opportunity ...
Marie Grobbelaar, Savvas Andronikou
doaj +4 more sources
Properties of Axial Diameters of a Simplex [PDF]
Let S be a nondegenerate simplex in ℝn . It is proved that the minimal possible σ>0, such that a homothetic copy of S of ratio σ contains [0,1]n , is equal to $\sum_{i=1}^{n} 1/d_{i}(S)$. Here d i (S) denotes the length of a longest segment in S parallel to the ith coordinate axis.
openaire +1 more source
Influence of Diameter Increase Speed on Diameter-Axial Rolling of Large 40Cr13 Stainless Steel Ring
Abstract Rolling speed ratios during the rolling process are critical to ring forming in this pepper. The selected roll feed mode is constant with the increasing speed of ring diameter during the main rolling stage. Based on Deform-3D finite element software, a large size ring with a diameter of φ1530 mm was taken as the research object.
Zhiqi Shi, Liping Shi, Sifu Cheng
openaire +1 more source
Properties of axial diameters [PDF]
Λ is a lattice and K a bounded, open, convex set in En. An axial diameter of K is the maximal length Xi, of chords of K parallel to the ith lattice basis vector (1 ≤ i ≤ n). A number of properties of the axial diameters are developed. For sets K containing just one lattice point, an inequality is established; when Λ is the integral lattice, this ...
openaire +2 more sources
On Some Results in the Geometry of Convex Bodies and their Applications
We give a survey of some results in the geometry of convex bodies and their applications.
M. V. Nevskii
doaj +1 more source
STRAIN GAUGE ANALYSIS OF AXIAL AND OFF AXIAL LOADING ON IMPLANTS FOR REPLACING FIRST MANDIBULAR MOLAR (INVITRO STUDY) [PDF]
INTRODUCTION: Mechanical overload is thought to be one of the major causes of implant complications. It may induce loosening and fracture of the superstructure and/or implant components. Bone loss may also occur at the implant-bone interface.
Mohammad S. Nassif +2 more
doaj +1 more source
Correlation Between Ciliary Sulcus Diameter and IOL Master Measurements in Patients with Cataract
Pur po se: To determine the mean sulcus diameters in patients older than 50 years with senile cataract and to analyze the correlations of sulcus diameters with IOLMaster measurements of corneal diameter (white to white), axial length, keratometry and ...
Alper Ağca +3 more
doaj +1 more source
EXPERIMENTAL STUDY OF LIQUID DISPERSION IN BUBBLE COLUMN
The main object of this study is to investigate the influence of column diameter and superficial gas velocity on liquid phase dispersion coefficients (axial and radial dispersion coefficients), mixing times, gas holdup, and bubble dynamics (bubble ...
Hayder Abd Al-kaream Muhsin
doaj +1 more source
Diameter-dependent axial prestretch of porcine coronary arteries and veins
The pressure-diameter relation (PDR) and the wall strain of coronary blood vessels have important implications for coronary blood flow and arthrosclerosis, respectively. Previous studies have shown that these mechanical quantities are significantly affected by the axial stretch of the vessels.
Xiaomei, Guo, Yi, Liu, Ghassan S, Kassab
openaire +3 more sources
Contribution to geometrical identification of carriers in radial axial bearings with big diameters [PDF]
Published
Milomir Gašić +5 more
openaire +2 more sources

