Results 91 to 100 of about 257,175 (322)

Design of a magnetostrictive (MS) actuator [PDF]

open access: yes, 2008
Several advanced technologies are introduced in automotive applications. Higher energy density and dynamic performance are demanding new and cost effective actuator structures. Magnetostriction (MS), change in shape of materials under the influence of an
A. Grunwald   +15 more
core   +1 more source

Tumour–host interactions in Drosophila: mechanisms in the tumour micro‐ and macroenvironment

open access: yesMolecular Oncology, EarlyView.
This review examines how tumour–host crosstalk takes place at multiple levels of biological organisation, from local cell competition and immune crosstalk to organism‐wide metabolic and physiological collapse. Here, we integrate findings from Drosophila melanogaster studies that reveal conserved mechanisms through which tumours hijack host systems to ...
José Teles‐Reis, Tor Erik Rusten
wiley   +1 more source

Identification of serum protein biomarkers for pre‐cancerous lesions associated with pancreatic ductal adenocarcinoma

open access: yesMolecular Oncology, EarlyView.
This work identified serum proteins associated with pancreatic epithelial neoplasms (PanINs) and early‐stage PDAC. Proteomics screens assessed genetically engineered mice with abundant PanINs, KPC mice (Lox‐STOP‐Lox‐KrasG12D/+ Lox‐STOP‐Lox‐Trp53R172H/+ Pdx1‐Cre) before PDAC development and also early‐stage PDAC patients (n = 31), compared to benign ...
Hannah Mearns   +10 more
wiley   +1 more source

Quantification of differential axial shortening in reinforced concrete and concrete-filled steel-tube-based building structures

open access: yesJournal of Asian Architecture and Building Engineering
This paper compares the axial shortening behaviors of reinforced concrete (RC) and concrete-filled tube (CFT) columns in high-rise building structures and proposes a relationship between the differential axial shortening and the dead load portion.
SeongHun Kim, Hyo-Gyoung Kwak
doaj   +1 more source

A novel device with pedicular anchorage provides better biomechanical properties than balloon kyphoplasty for the treatment of vertebral compression fractures

open access: yesJournal of Experimental Orthopaedics, 2023
Purpose To compare the biomechanical behavior of vertebrae with vertebral compression fractures (VCF) treated by a novel system with pedicular anchorage (dowelplasty) versus balloon kyphoplasty.
Jean‐Charles Le Huec   +5 more
doaj   +1 more source

An analytical model for elasto-plastic buckling of columns [PDF]

open access: yes, 2013
The theory of buckling strength of compression members in the plastic range has been extensively studied, and numerical methods already exist which deal with such behaviour.
Izzuddin, B.A., Jowhari Moghadam, S.
core  

Genetic attenuation of ALDH1A1 increases metastatic potential and aggressiveness in colorectal cancer

open access: yesMolecular Oncology, EarlyView.
Aldehyde dehydrogenase 1A1 (ALDH1A1) is a cancer stem cell marker in several malignancies. We established a novel epithelial cell line from rectal adenocarcinoma with unique overexpression of this enzyme. Genetic attenuation of ALDH1A1 led to increased invasive capacity and metastatic potential, the inhibition of proliferation activity, and ultimately ...
Martina Poturnajova   +25 more
wiley   +1 more source

Determination of Axial Force in Tie Rods of Historical Buildings Using the Model-Updating Technique

open access: yesApplied Sciences, 2020
Tie rods are structural elements that transfer axial tensile loads and are typically used on walls, vaults, arches, and buttresses in historical buildings.
Ivan Duvnjak   +3 more
doaj   +1 more source

Experimental and analytical determination of characteristics affecting light aircraft landing-gear dynamics [PDF]

open access: yes
An experimental and analytical investigation was conducted to determine which characteristics of a light aircraft landing gear influence gear dynamic behavior significantly. The investigation focused particularly on possible modification for load control.
Fasanella, E. L.   +2 more
core   +1 more source

Measuring the notched compressive strength of composite laminates: Specimen size effects [PDF]

open access: yes, 2008
Large fibre reinforced composite structures can give much lower strengths than small test specimens, so a proper understanding of scaling is vital for their safe and efficient use.
C. Soutis   +15 more
core   +3 more sources

Home - About - Disclaimer - Privacy