Results 41 to 50 of about 52,179 (162)
In this paper, the damage of a reinforced concrete (RC) column with various levels of reinforcement corrosion under axial loads is characterized using the acoustic emission (AE) technique.
Ye Chen +8 more
doaj +1 more source
In this paper, a complicated single-degree-of-freedom (SDOF) approach was developed to determine the global response of steel columns under combined axial and blast-induced transverse loads.
Junbo Yan, Yan Liu, Fenglei Huang
doaj +1 more source
123 withdrawal tests were conducted to investigate the change in axial stiffness of fully threaded screws under axial loading and up to four loading cycles.
Sebastian Egner, Philipp Dietsch
doaj +1 more source
External Strengthening of Corrosion-Defected Beam–Column Members Using a CFRP Sheet
The efficiency of external strengthening using CFRP (Carbon Fiber Reinforced Polymer) sheets to rehabilitate corrosion-defected RC (Reinforced Concrete) beam−column members is experimentally studied. ALL specimens were tested under a combined axial
Nameer A. Alwash +2 more
doaj +1 more source
RC wall and steel side columns coupled structural system: Experimental and numerical investigations
The reinforced concrete (RC) wall coupled with steel side columns (SSC) using steel coupling beams were studied both experimentally and numerically. A 1/4 scaled 5-story test model was constructed and tested to failure under reversed lateral cyclic and ...
Y.T. Wu +4 more
doaj +1 more source
Betonun basınç dayanımı, betonarme sistemin yapısal bütünlüğü açısından hayati önem taşımaktadır. Gerek inşaat aşamasında gerekse inşaat tamamlandıktan sonra, farklı yapı elemanlarındaki basınç dayanımlarının bilinmesi, kontrol ve değerlendirme ...
Yusuf Demirel
doaj
The behavior of ultra-high-strength reinforced concrete columns under axial and cyclic lateral loads
In general Ultra High Strength Concrete (UHSC) is a new class of concrete that has been developed in recent decades. UHSC is characterized by extraordinary mechanical and durability properties. The UHSC-Matrix is very brittle material behavior.
Mohamed M. EL-Attar +2 more
doaj +1 more source
Background Distal first metatarsal osteotomy is used to correct mild or moderate hallux valgus (HV). We designed a cadaveric study to compare the resistance to axial load between two percutaneous distal first metatarsal osteotomies: Bösch osteotomy and ...
Ester Navarro-Cano +7 more
doaj +1 more source
Determination of Axial Force in Tie Rods of Historical Buildings Using the Model-Updating Technique
Tie rods are structural elements that transfer axial tensile loads and are typically used on walls, vaults, arches, and buttresses in historical buildings.
Ivan Duvnjak +3 more
doaj +1 more source
Purpose To compare the biomechanical behavior of vertebrae with vertebral compression fractures (VCF) treated by a novel system with pedicular anchorage (dowelplasty) versus balloon kyphoplasty.
Jean‐Charles Le Huec +5 more
doaj +1 more source