Results 1 to 10 of about 21,033 (238)
Backflow Power Optimization Control for Dual Active Bridge DC-DC Converters [PDF]
This paper proposes optimized control methods for global minimum backflow power based on a triple-phase-shift (TPS) control strategy. Three global optimized methods are derived to minimize the backflow power on the primary side, on the secondary side and
Fei Xiong +3 more
doaj +2 more sources
Simulations to Eliminate Backflow Power in an Isolated Three-Port Bidirectional DC–DC Converter
The aim of this work was to eliminate the backflow power present in an isolated three-port DC–DC converter. Backflow power (which is an inherent property of phase-shifted DC–DC converters) is the major contributor of circulating current the converter ...
Norbert Njuanyi Koneh +2 more
doaj +2 more sources
Backflow Power Optimization of DAB Based on Asymmetric Duty Cycle and Internal Phase Shift Control
Dual active bridge (DAB) converter with single-phase-shifting (SPS) control would produce large backflow power when voltage regulation ratio deviates from 1 or under light load, an asymmetric duty cycle and internal phase shift (ADIPS) control was ...
Fei Xie, Hao Wang, Jie Shu
doaj +2 more sources
Dual-active bridge (DAB) converters are receiving increasing attention from researchers as a critical part of the power transmission of energy routers. However, the DAB converter generates a large backflow power in conventional control mode, and when the
Xinwen Zhang, Canlong Wang
doaj +2 more sources
Hybrid modulation strategy for minimizing backflow power under dual phase shift modulation
The dual active bridge (DAB) converter is essential for direct current (DC) microgrids, providing galvanic isolation, high power density, and bidirectional power transfer.
Xiaoqian Yue +4 more
doaj +2 more sources
Modulation of a semi dual‐active‐bridge resonant converter with soft‐switching and zero backflow power [PDF]
In this paper, two phase‐shift angles plus switching frequency are modulated to control a semi dual‐active‐bridge resonant converter. The full operation map with distinctive steady‐state modes under the multi‐dimensional control is constructed at first ...
Sheng‐Zhi Zhou +3 more
doaj +2 more sources
An Intelligent Floor Drain System for Self-Powered Disinfection via Low-Velocity Wastewater Energy Harvesting [PDF]
Rapid urbanization intensifies hygiene and sustainability challenges in drainage systems, where conventional floor drains suffer from odor backflow, bacterial growth, and pathogen transmission.
Zhijie Huang +5 more
doaj +2 more sources
Experimental study on dynamic evolutions of airflow in the ventilation network under the effect of mine gas outburst disasters [PDF]
Coal and gas outbursts represent a complex and dynamic phenomenon. To further clarify dynamic evolutions of airflow under the effect of gas outburst disasters, an experimental device for simulating gas-induced airflow disturbance under the circumstances ...
Jingxiao Yu +4 more
doaj +2 more sources
The LLC-type resonant dual-active-bridge (LLC-DAB) DC-DC converter with a high voltage gain, high power density, and low backflow power has attracted increasing attention in recent years.
Zimeng Li +5 more
doaj +1 more source
The LCL-type dual active bridge (LCL-DAB) DC-DC converter is a promising part for DC micro-grids due to its high voltage gain and low bridge current, but the issues of backflow power elimination and transient response optimization deserve attention in ...
Mingxue Li +6 more
doaj +1 more source

