Results 41 to 50 of about 4,334 (147)
Optimal Design in Roller Pump System Applications for Linear Infusion
In this study, an infusion roller pump comprising two separate innovative resilient tube designs is presented. The first incorporates the flexible tubing cross-section area in its relaxed state as a lenticular one for power reduction reasons.
Christos Manopoulos +6 more
doaj +1 more source
Modular dual-active-bridge (DAB) converter is widely used for fast electric vehicle (EV) charging due to galvanic isolation and high power processing capability.
Jiayi Geng +3 more
doaj +1 more source
In order to prevent the backward flow of piezoelectric pumps, this paper presents a single-active-chamber piezoelectric membrane pump with multiple passive check valves.
Ronghui Zhang +5 more
doaj +1 more source
DAB minimum current stress segmented optimal control strategy based on extended phase shift control
To address the issue of low transmission efficiency in dual active bridge (DAB) converters during electric vehicle charging and discharging processes, a minimum current stress optimization control strategy combining the differential extremum method with ...
Xingguo TAN +4 more
doaj +1 more source
Global flow behaviors of multiple shafts in shallow-buried urban road tunnels subjected to fire load
Shallow-buried urban road tunnels with shafts (URTS) have reduced traffic congestion in large cities. During fire scenarios, the backflows occur at those shafts far away from the fire source inhibiting smoke exhaust, but its rules have been unknown.
Daolong Xiong +7 more
doaj +1 more source
Research on Control Strategy of EMU Bidirectional Charger Based on DAB Circuit
In order to simplify the topology structure of the traditional EMU charger, reduce the volume and weight of the equipment and improve the safety, the DAB was applied to the EMU charger.
Bingzhang LI +5 more
doaj
Abstract In view of the power backflow phenomenon in provincial transmission and distribution network caused by the fact that more and more new energy power is connected to the power grid, a provincial network voltage level pricing method considering power backflow is proposed.
Qian Junjie +4 more
openaire +1 more source
Direct lightning strokes are considered to be a main cause of damage to surge arresters on power distribution lines. Recently, lightning performance of distribution lines has been observed using still cameras, and lightning-caused distribution outages on hilltop areas on the coast of the Sea of Japan have been investigated.
Kazuo Nakada +4 more
openaire +2 more sources
Abstract This paper proposes a single-stage isolated converter with a backflow power optimization method for V2G charging piles. The modulation algorithm is optimized, and the phase shifts are designed to minimize the backflow power. Due to the suppression of backflow power during the switching period, the power factor correction (PFC ...
Qingxiang Shen, Tengfei Yao
openaire +1 more source
Dynamic and flow instability analysis during runaway process for a pump turbine
A power failure in the pump condition combined with the rejection of the guide vanes can cause the unit to runaway, which represents a dangerous transitional process for pumped storage power stations.
Yanyan Li +3 more
doaj +1 more source

