Results 51 to 60 of about 4,334 (147)
This paper introduces a method for deriving an optimal closed-form solution for extended phase shift (EPS) control of a dual active bridge (DAB) DC-DC converter, capable of achieving both minimum backflow power (MBP) and zero-voltage switching (ZVS ...
Nguyen Ngoc Nam +2 more
doaj +1 more source
The diversion effect caused by the linked structure in a metro tunnel with cross-passage complicates the impact of longitudinal fire source location on the smoke backflow layering behavior that has not been clarified, despite the fact that the scenario ...
Zhisheng Li +4 more
doaj +1 more source
To address the drawbacks of traditional hydraulic power units, we embedded a 2D piston pump inside the motor rotor, proposing a 2D piston electro-hydraulic pump.
Xin-Guo Qiu +5 more
doaj +1 more source
In order to investigate the influence of ventilation velocity on fire smoke distribution in bifurcated roadway, the computational fluid dynamics (CFD) numerical method was adopted to simulate the fires located in upstream of main-roadway.
Cui DING
doaj +1 more source
An Enhanced Fault Ride‐Through Control Method of the VSG Based on Dynamic Power Compensation
Virtual synchronous generators (VSGs) based inverters have been widely applied for active frequency and voltage support. However, when the grid encounters unexpected large disturbances, like voltage drops, the power electronic components of the inverters
Xueqing Li +5 more
doaj +1 more source
To further study the influence of heat exchanger structures on system performance and overall power consumption in transcritical CO2 heat pump air conditioning systems for high-speed trains to improve performance and reduce power consumption, this study ...
Xie Hongsheng +4 more
doaj
BackgroundIn thermal pipelines of nuclear power systems, thermal stratification is a common phenomenon that can cause stress concentration and deformation of pipeline structures, thereby leading to safety hazards.
MA Jingxiang +2 more
doaj +1 more source
Dual-Transformer Series Resonant Converter with Full Range ZVS Operation
A dual-transformer series resonant converter (DTSRC) is proposed to solve the problem of excessive return power and loss of zero voltage switching (ZVS) operation under light load in the dual bridge resonant converter (DBRC). A dual-transformer structure
LI Yinan, HU Song, LI Xiaodong, CHEN Wu, ZHONG Liping, YANG Qingqing
doaj +1 more source
With the advantages of simple topology, voltage matching, electrical isolation, and bi-directional energy control, the Triple Active Bridge (TAB) has become an active area of exploration and research for the flexible interconnection of DC ports, such as ...
Qihui Feng +5 more
doaj +1 more source
Vehicle-to-Grid (V2G) electric vehicle chargers are becoming increasingly important due to their potential to enhance grid stability, support renewable energy integration, and provide economic benefits. This has led to a growing demand for dual active bridge (DAB) bidirectional DC-DC converters.
Wang, Kun, Laird, Ian, Wang, Jun
openaire +2 more sources

