Evaluation of the Electron Contamination in Photon Therapy Using BEAMnrc Code
Background: Today, high-energy photon beams are widely used in the treatment of all types of cancers. However, the production of electrons as contaminants in the photon pathway provides the necessity for research in this field.
Nahid Chegeni +3 more
doaj +3 more sources
Purpose: Gamma Knife is applied as a superseded tool for inaccessible lesions surgery delivering a single high dose to a well-defined target through 201 small beams. Monte Carlo simulations can be an appropriate supplementary tool to determine dosimetric
Atefeh Mahmoudi, Ghazale Geraily
doaj +3 more sources
Monte carlo simulation of siemens oncor linear accelerator with beamnrc and dosxyznrc code
The Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers.
Keyvan Jabbari +3 more
doaj +3 more sources
Feasibility study: Use of an optical scanning system to obtain 3D body surface images suitable for total skin electron therapy treatment dosimetry. [PDF]
Abstract Background Total skin electron therapy (TSET, also known as TSE, TSI, TSEI or TSEBT) provides an effective treatment for extensive superficial lesions such as mycosis fungoides, although the standing setups and large distances used for treatment mean that comprehensive three‐dimensional (3D) dose calculations are rarely achievable clinically ...
Crowe SB +4 more
europepmc +2 more sources
Monte Carlo simulation of a multi-leaf collimator design for telecobalt machine using BEAMnrc code
This investigation aims to design a practical multi-leaf collimator (MLC) system for the cobalt teletherapy machine and check its radiation properties using the Monte Carlo (MC) method.
Ayyangar Komanduri +4 more
doaj +3 more sources
Evaluation of extrapolation chamber response for surface and buildup dose assessment in radiotherapy photon beams using Monte Carlo simulations. [PDF]
Abstract Background Surface dose assessment is essential in radiotherapy, but accurately measuring doses in the buildup region of megavoltage beams presents significant challenges. Extrapolation chambers are frequently regarded as the most suitable detectors for this purpose. Purpose To establish under what conditions extrapolation chambers can be used
Reis CQM +3 more
europepmc +2 more sources
Field output correction factors and perturbation factor analysis for novel SunSILICON and SunSILICON P silicon diode detectors. [PDF]
Abstract Background Field output factor measurements of clinical linear accelerators require detector‐specific corrections, due to the introduction of fluence perturbation effects by non‐water‐equivalent components of applied detectors. Purpose This study aims to determine field output correction factors for novel shielded and unshielded silicon diode ...
Schönfeld AA +13 more
europepmc +2 more sources
Monte Carlo modeling of the Elekta Versa HD and patient dose calculation with EGSnrc/BEAMnrc. [PDF]
AbstractIntroductionNumerous studies have proven the Monte Carlo method to be an accurate means of dose calculation. Although there are several commercial Monte Carlo treatment planning systems (TPSs), some clinics may not have access to these resources.
Paschal HMP +6 more
europepmc +3 more sources
Monte Carlo modeling of the origin of contaminant electrons on a 0.5T bi-planar Linac-MR. [PDF]
Abstract Introduction In the last decade, hybrid linear accelerator magnetic resonance imaging (Linac‐MR) devices have evolved into FDA‐cleared clinical tools, facilitating magnetic resonance guided radiotherapy (MRgRT). The addition of a magnetic field to radiation therapy has previously demonstrated dosimetric and electron effects regardless of ...
Reynolds M +7 more
europepmc +2 more sources
The dosimetric effect of photon target degradation on C-series linear accelerators using Monte Carlo simulation. [PDF]
Abstract Background The impact of beam dosimetry changes brought on by target degradation has not been well investigated. Purpose To determine the optimal dosimetry metrics for detecting target degradation and to investigate the impact of beam dosimetry changes brought on by target degradation. Methods The EGSnrc Monte Carlo programs were used to model
Deng Y, Qiu M, Zhong J, Xiao Z.
europepmc +2 more sources

