Results 1 to 10 of about 1,530,338 (157)

Validation and automation of the DYNJAWS component module of the BEAMnrc Monte Carlo code [PDF]

open access: yesAustralasian Physical and Engineering Sciences in Medicine, 2011
The purpose of this work is to validate and automate the use of DYNJAWS; a new component module (CM) in the BEAMnrc Monte Carlo (MC) user code. The DYNJAWS CM simulates dynamic wedges and can be used in three modes; dynamic, step-and-shoot and static.
Andrew Fielding   +2 more
exaly   +7 more sources

Monte Carlo simulation of a multi-leaf collimator design for telecobalt machine using BEAMnrc code [PDF]

open access: yesJournal of Medical Physics, 2010
This investigation aims to design a practical multi-leaf collimator (MLC) system for the cobalt teletherapy machine and check its radiation properties using the Monte Carlo (MC) method.
Ayyangar Komanduri   +4 more
doaj   +4 more sources

Monte Carlo Simulation-Based BEAMnrc Code of a 6 MV Photon Beam Produced by a Linear Accelerator (LINAC) [PDF]

open access: yesAtom Indonesia, 2021
In radiotherapy, high energy ionizing radiation, such as X-rays, gamma rays and electron beams,is used. The dose in the tissue is often approached with the dose in the medium of the body which is 80 % of human soft tissue.
R. Sapundani, R. Ekawati, K. M. Wibowo
doaj   +5 more sources

Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package [PDF]

open access: yesBiomedical Engineering and Computational Biology, 2022
Introduction: EGSnrc software package is one of the computational packages for Monte Carlo simulation in radiation therapy and has several subset codes.
Razzagh Abedi Firouzjah   +1 more
exaly   +3 more sources

EGSnrc/BEAMnrc-Based Monte Carlo Simulation of the Gamma Knife 4C versus MCNP Code in Homogeneous Media

open access: yesFrontiers in Biomedical Technologies, 2020
Purpose: Gamma Knife is applied as a superseded tool for inaccessible lesions surgery delivering a single high dose to a well-defined target through 201 small beams. Monte Carlo simulations can be an appropriate supplementary tool to determine dosimetric
Atefeh Mahmoudi, Ghazale Geraily
doaj   +4 more sources

Monte Carlo Simulation for the Radixact™ Tomotherapy Linac Using EGSnrc [PDF]

open access: yesJournal of Medical Physics
Purpose: When exact information regarding the treatment head and initial electron beam is available, the Monte Carlo (MC) approach can properly simulate any linear accelerator. However, manufacturers seldom offer information such as the incident electron
Danial Seifi Makrani   +5 more
doaj   +2 more sources

Evaluation of the Electron Contamination in Photon Therapy Using BEAMnrc Code

open access: yesمجله دانشکده پزشکی اصفهان, 2019
Background: Today, high-energy photon beams are widely used in the treatment of all types of cancers. However, the production of electrons as contaminants in the photon pathway provides the necessity for research in this field.
Nahid Chegeni   +3 more
doaj   +2 more sources

Design and evaluation of structural shielding of a typical radiotherapy facility using egsnrc monte carlo code [PDF]

open access: yesJournal of Medical Physics, 2022
Purpose: This study aimed to evaluate the shielding integrity of a typical radiotherapy facility using the Monte Carlo (MC) method. Materials and Methods: EGSnrc MC code was used to design a radiotherapy bunker with appropriate materials and thicknesses.
Zaccheaus Ayo Ibitoye   +3 more
doaj   +2 more sources

Validation of a 10 MV photon beam Elekta Synergy linear accelerator using the BEAMnrc MC code

open access: yesJournal of King Saud University - Science, 2021
Abstract Objective: The Monte Carlo (MC) technique can accurately model any linear accelerator where accurate details about the treatment head and the incident electron beam have been provided. However, manufacturers generally do not provide such details as the energy, radial intensity (spot size), or the angular spread of the incident electron beam.
Turki Almatani
exaly   +2 more sources

Validation of Monte Carlo-based calculations for megavolt electron beams for IORT and FLASH-IORT [PDF]

open access: yesHeliyon, 2022
In Intra-Operative Radiation Therapy (IORT) the tumour site is surgically exposed and normal tissue located around the tumour may be avoided. Electron applicators would require large surgical incisions; therefore, the preferred mechanism for beam ...
Graeme L. Lazarus   +2 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy