Assessment of the Absorbed Dose Variations in the Thyroid Gland Exposed to Orthopantomography (OPG) while Swallowing: A Novel Approach to Radiation Protection [PDF]
Background: The reliance on specialized diagnostic techniques is on the rise across various medical fields, including dentistry. While orthopantomogram (OPG), offers many advantages in terms of dental diagnosis, it also poses potential risks to sensitive
Hassan Vafapour, Zaker Salehi
doaj +2 more sources
The BEAMnrc code was used for the simulation of the Theratron Equinox-80 telecobalt machine. The phase space of radiation beam was generated at treatment distance of 80 cm for various field sizes. The phase spaces in air were analyzed by BEAMdp data processing program.
Narayan Prasad Patel +6 more
exaly +3 more sources
Feasibility study: Use of an optical scanning system to obtain 3D body surface images suitable for total skin electron therapy treatment dosimetry. [PDF]
Abstract Background Total skin electron therapy (TSET, also known as TSE, TSI, TSEI or TSEBT) provides an effective treatment for extensive superficial lesions such as mycosis fungoides, although the standing setups and large distances used for treatment mean that comprehensive three‐dimensional (3D) dose calculations are rarely achievable clinically ...
Crowe SB +4 more
europepmc +2 more sources
Development of a LINAC head model for the CyberKnife VSI-System using EGSnrc Monte Carlo system. [PDF]
Abstract Introduction In order to understand the interaction processes of photons and electrons of the CyberKnife VSI‐System, a modeling of the LINAC head must take place. Here, a Monte Carlo simulation can help. By comparing the measured data with the simulation data, the agreement can be checked. Materials and methods For the Monte Carlo simulations,
Thiele M, Galonske K, Ernst I, Mack A.
europepmc +2 more sources
Field output correction factors and perturbation factor analysis for novel SunSILICON and SunSILICON P silicon diode detectors. [PDF]
Abstract Background Field output factor measurements of clinical linear accelerators require detector‐specific corrections, due to the introduction of fluence perturbation effects by non‐water‐equivalent components of applied detectors. Purpose This study aims to determine field output correction factors for novel shielded and unshielded silicon diode ...
Schönfeld AA +13 more
europepmc +2 more sources
Monte Carlo modeling of the origin of contaminant electrons on a 0.5T bi-planar Linac-MR. [PDF]
Abstract Introduction In the last decade, hybrid linear accelerator magnetic resonance imaging (Linac‐MR) devices have evolved into FDA‐cleared clinical tools, facilitating magnetic resonance guided radiotherapy (MRgRT). The addition of a magnetic field to radiation therapy has previously demonstrated dosimetric and electron effects regardless of ...
Reynolds M +7 more
europepmc +2 more sources
Clinical performance of a shielded diode for small field relative dosimetry in a 1.5 T MRI-linac using measurements and simulations. [PDF]
Abstract Background Small field dosimetry on magnetic‐resonance (MR) guided linear accelerators (linacs) has become increasingly more important for accurate beam modeling due to the increase in the number of patients and variety of disease sites treated on MR‐linacs such as those with small fields.
Ferris WS +3 more
europepmc +2 more sources
Electron modes simulation of a Siemens-Primus-Linac at 10, 12, and 14 MeV with various field sizes
The electron mode of a Siemens Primus linear accelerator (SPLA) is simulated using Monte Carlo (MC) simulation, BEAMnrc, with various field sizes 10 × 10, 15 × 15, and 20 × 20 cm2 at different e-beam energies of 10, 12, 14 MeV.
Hani H. Negm +2 more
doaj +1 more source
Radiology and mammography standard X-ray spectra simulated with the Monte Carlo method
Six standard beams described in the TRS-457 (IAEA): RQR 5, 8, M1, M2, M3, M4 were simulated using the EGSnrc Monte Carlo code. Each spectrum was created by an X-ray tube simulated in BEAMnrc, and attenuation curves were obtained using the application ...
Joel Marques Xavier Filho +2 more
doaj +1 more source
Monte Carlo modeling of radiation dose from radiation therapy with superficial x-rays. [PDF]
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Barghash R +3 more
europepmc +2 more sources

