Results 131 to 140 of about 1,530,338 (157)
openaire +1 more source
Simulating oblique incident irradiation using the BEAMnrc Monte Carlo code
A new source for the simulation of oblique incident irradiation has been developed for the BEAMnrc Monte Carlo code. In this work, we describe a method for the simulation of any component that is rotated at some angle relative to the central axis of the modelled radiation unit.
Emiliano Spezi
exaly +4 more sources
SU‐FF‐I‐25: Feasibility of Estimating Multidetector CT Dose Using BEAMnrc Code
Purpose: Most of Monte Carlo based methods estimating radiation dose in computed tomography (CT) were performed using MCNP or EGS codes. The BEAMnrc code, one of Monte Carlo codes, was usually used to simulate radiation therapy accelerators, and has fine graphic interfaces and various component modules.
C C Chiang‐Hsieh +2 more
openaire +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Physics of Particles and Nuclei Letters, 2017
The Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy and beam characterization investigation, in this study, the Varian Clinac 2100 medical linear accelerator with and without flattening filter (FF) was modelled.
Mohamed Bencheikh +2 more
exaly +2 more sources
The Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy and beam characterization investigation, in this study, the Varian Clinac 2100 medical linear accelerator with and without flattening filter (FF) was modelled.
Mohamed Bencheikh +2 more
exaly +2 more sources
Physics of Particles and Nuclei Letters, 2017
The Monte Carlo model for the photon-beam output from the Varian Clinac 2100 linear accelerator was validated to compare the calculated to measured PDD and beam dose profiles The Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy.
Ahad Ollah Ezzati +2 more
exaly +2 more sources
The Monte Carlo model for the photon-beam output from the Varian Clinac 2100 linear accelerator was validated to compare the calculated to measured PDD and beam dose profiles The Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy.
Ahad Ollah Ezzati +2 more
exaly +2 more sources
Moscow University Physics Bulletin (English Translation of Vestnik Moskovskogo Universiteta, Fizika), 2017
Determination and understanding the photon beam attenuation by the photon beam modifier and the radiation beam softening for clinical use is more important part of material study for the beam modifier enhancements and the linac improvements. A Monte Carlo model was used to simulate 6 MeV photon beams from a Varian Clinac 2100 accelerator with the ...
Mohamed Bencheikh +2 more
exaly +2 more sources
Determination and understanding the photon beam attenuation by the photon beam modifier and the radiation beam softening for clinical use is more important part of material study for the beam modifier enhancements and the linac improvements. A Monte Carlo model was used to simulate 6 MeV photon beams from a Varian Clinac 2100 accelerator with the ...
Mohamed Bencheikh +2 more
exaly +2 more sources
Monte Carlo simulation of Varian Linac for 6 MV photon beam with BEAMnrc code
Radiation Physics and Chemistry, 2018Abstract The purpose of this study is to investigate the effects of the initial electron beam parameters on the absorbed dose distribution calculated with EGSnrc Monte Carlo code, for 6 MV photon beam. A proposed methodology for benchmarking the BEAMnrc model of Varian Linac has been used.
Maged Mohammed +2 more
exaly +2 more sources
VMC versus BEAMnrc: A comparison of simulated linear accelerator heads for photon beams
BEAMnrc, a code for simulating medical linear accelerators based on EGSnrc, has been bench-marked and used extensively in the scientific literature and is therefore often considered to be the gold standard for Monte Carlo simulations for radiotherapy ...
E. J. Born +14 more
exaly +2 more sources
In the present work, Monte Carlo (MC) models of electron beams (energies 4, 12 and 18MeV) from an Elekta SL25 medical linear accelerator were simulated using EGSnrc/BEAMnrc user code.
S Vynckier
exaly +2 more sources
Study of unflattened photon beams shaped by multileaf collimator using BEAMnrc code
Journal of Radiotherapy in Practice, 2016AbstractPurposeIn our study basic dosimetric properties of a flattening filter free 6 MV photon beam shaped by multileaf collimators (MLC) is examined using the Monte Carlo (MC) method.Methods and MaterialsBEAMnrc code was used to make a MC simulation model for 6 MV photon beam based on Varian Clinic 600 unique performance linac, operated with and ...
Ankit kajaria +5 more
openaire +1 more source