Bicuspid aortic valve (BAV) has a prevalence of 0.5–1.39% in the general population. The prevalence of BAV in aortic dissection is 3.5–11.8%. Unfortunately, the incidence of aortic dissection in BAV remains unknown. The etiology of BAV is polygenetic, where environmental factors and unknown genetic factors seem to interact to cause BAV.
Christopher, Harris +2 more
+5 more sources
The first clinical data of the SAPIEN 3 aortic valve in the treatment of aortic stenosis in China
BackgroundData on outcomes following transcatheter aortic valve replacement with SAPIEN 3 in China is limited as it was approved by the National Medical Products since 2020.
Xiaoke Shang +16 more
doaj +1 more source
PATHOPHYSIOLOGY, INVESTIGATIONS, AND TREATMENT OF PATIENTS WITH BICUSPID AORTIC VALVE [PDF]
Bicuspid aortic valve is a congenital anomaly of the heart in which the aortic valve has two loops instead of the normal three. It causes valve degeneration and is associated with dilation of the aorta.
Elsaka, O. +11 more
core +2 more sources
The purpose of this study was to evaluate whether bicuspid anatomy affects the discrepancy between CT-derived annular size and intraoperative size. We retrospectively analyzed annular measurements in 667 patients who underwent surgical aortic valve ...
Jooae Choe +5 more
doaj +1 more source
BackgroundClinical evidence of transcatheter aortic valve replacement in patients with type-0 bicuspid aortic valve was relatively scarce.AimsOur goal was to explore determinants of device success after transcatheter aortic valve replacement in patients ...
Zhicheng Xiao +9 more
doaj +1 more source
Background: Antibiotic prophylaxis in bicuspid aortic valve patients is currently a matter of debate. Although it is no longer recommended by international guidelines, some studies indicate a high risk of infective endocarditis.
Sara Couto Pereira +8 more
doaj +1 more source
Transcatheter aortic valve implantation (TAVI) for bicuspid aortic valve stenosis can pose several technical challenges including difficult valve crossing.
Bilal Bawamia +3 more
doaj +1 more source
Point on the Aortic Bicuspid Valve
Background—Bicuspid aortic valve (BAV) disease is the most prevalent congenital heart disease in the world. Knowledge about its subtypes origin, development, and evolution is poor despite the frequency and the potential gravity of this condition. Its prognosis mostly depends on the risk of aortic aneurysm development with an increased risk of aortic ...
Chloé Bernard +4 more
openaire +3 more sources
: Background: Bicuspid aortic valve (BAV) is the most common congenital heart disease, often associated with valve dysfunction, coarctation of the aorta, and ascending aorta dilatation.
Franco-Cereceda, Anders +37 more
core +1 more source
Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve
Abstract Transcatheter aortic valve replacement (TAVR) is being routinely done in various centres for aortic stenosis due to tricuspid aortic valves. The number of TAVR procedures are increasing, but the data on bicuspid aortic valves (BAV) is scanty. BAV is commonest abnormality in general population and can progress to severe aortic
Immaneni Sathyamurthy, Sai Satish
openaire +2 more sources