Results 41 to 50 of about 22,875,305 (292)

A single weekly Kt/Vurea target for peritoneal dialysis patients does not provide an equal dialysis dose for all [PDF]

open access: yes, 2016
Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.Dialysis adequacy is traditionally based on urea clearance, adjusted for total body volume (Kt/Vurea), and clinical guidelines recommend a Kt/Vurea ...
Davenport, Andrew   +4 more
core   +2 more sources

The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of Diseases

open access: yesSensors, 2014
Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range
Sami F. Khalil   +2 more
doaj   +1 more source

Justification of the need to create a new classification of obesity

open access: yesЛечащий Врач, 2021
The results of numerous studies conducted over the past decades have shown that the greatest importance in determining the risk of disease and death at the individual level is the accumulation of visceral adipose tissue, associated with the development ...
S. V. Miklishanskaya   +4 more
doaj   +1 more source

Bioimpedance analysis is not superior to clinical assessment in determining hydration status: A prospective randomized‐controlled trial in a Western dialysis population

open access: yesHemodialysis international. International Symposium on Home Hemodialysis, 2021
Fluid management is an important goal of dialysis treatment. The accurate assessment of fluid status is still a challenge for clinical nephrologists. Bioimpedance analysis (BIA) has been proposed as an objective tool to assess hydration.
C. Sommerer   +4 more
semanticscholar   +1 more source

A Sinusoidal Current Driver With an Extended Frequency Range and Multifrequency Operation for Bioimpedance Applications [PDF]

open access: yes, 2014
This paper describes an alternative sinusoidal current driver suitable for bioimpedance applications where high frequency operation is required. The circuit is based on a transconductor and provides current outputs with low phase error for frequencies ...
Demosthenous, A   +2 more
core   +1 more source

Body image perception and body composition: assessment of perception inconsistency by a new index [PDF]

open access: yes, 2020
BACKGROUND: A correct perception of the body image, as defined by comparison with actual anthropometric analyses, is crucial to ensure the best possible nutritional status of each individual.
Bramanti, B.   +4 more
core   +1 more source

Cost-effectiveness and value of information analysis of multiple frequency bioimpedance devices for fluid management in people with chronic kidney disease having dialysis

open access: yesCost Effectiveness and Resource Allocation, 2021
Background Among people with chronic kidney disease (CKD) on dialysis, sub-optimal fluid management has been linked with hospitalisation, cardiovascular complications and death.
Elisabet Jacobsen   +5 more
doaj   +1 more source

Phase Angle in Head and Neck Cancer: A Sex-Differential Analysis from Biological and Clinical Behavior to Health-Related Quality of Life

open access: yesBiomedicines, 2023
Head and neck cancer (H&NC) is a diverse category of tumors related to malignancies in the common aerodigestive pathway, with high metabolic rate, poor nutritional and treatment outcomes, and elevated mortality despite the best standard treatment. Herein,
Brenda-Eugenia Martínez-Herrera   +16 more
doaj   +1 more source

Hemodynamic Evaluation of Nonselective \u3b2-Blockers in Patients with Cirrhosis and Refractory Ascites [PDF]

open access: yes, 2018
BACKGROUND:Nonselective \u3b2-blockers (NSBB) have been associated with increased incidence of paracentesis-induced circulatory dysfunction (PICD) and reduced survival in patients with cirrhosis and refractory ascites.
Angeli, Paolo   +10 more
core   +2 more sources

Comparison between anthropometry and multi-frequency bioimpedance for body composition evaluation in Brazilian elite U-20 soccer athletes

open access: yesMotricidade, 2020
Young soccer players undertake anthropometric measurements for directing the effectiveness of training programs. However, the use of the eight-electrode electrical bioimpedance method is increasingly being used for the body composition evaluation.
Carlos Vinicius Herdy   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy