Important Features of Blood Glucose Meters
Journal of the American Pharmaceutical Association (1996), 1998To provide an overview of several blood glucose meters that will enhance practicing pharmacists' knowledge and understanding of these devices to allow education of the patient with diabetes.Original and review articles, blood glucose meter package inserts and manuals.Careful blood glucose control is essential to prevent long-term complications of ...
J K, Kirk, C C, Rheney
openaire +2 more sources
Performance of Three Blood Glucose Meters
The Annals of Pharmacotherapy, 2000OBJECTIVE: To evaluate the performance of three blood glucose meters. METHODS: The One Touch II (LifeScan, Milpitas, CA), Glucometer Elite (Bayer, Elkhart, IN), and Accu-Chek Advantage (Boehringer Mannheim, Indianapolis, IN) were ...
C C, Rheney, J K, Kirk
openaire +2 more sources
Development of the Portable Blood Glucose Meter for Self-monitoring of Blood Glucose
2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, 2005The work outlined in this paper is towards developing a portable, economy blood glucose meter for self-monitoring of blood glucose, which has high performance-price ratio with multifunction and is attractive to the average people. Its functions include blood glucose concentration measurement, LCD display, historical records restore, calendar/timer.
Qi, Li, Jingqi, Yuan
openaire +2 more sources
The utility of blood glucose meters in biotechnological applications
Biotechnology and Applied Biochemistry, 2005Most methods used to measure glucose concentrations in biotechnological settings are labourāintensive and/or expensive. With this in mind we have investigated the possibility of employing blood glucose meters, the use of which has the benefit of being fast, convenient and inexpensive, for this purpose.
Jennifer, FitzGerald, Wilfred, Vermerris
openaire +2 more sources
An Assessment of the Boehringer Advantage Blood Glucose Meter
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1997Blood glucose meters have been in use in the North Down and Ards Hospital Trust for the last 8 years. Our initial assessments'< had shown the Boehringer Reflolux 11 to be the instrument of choice. Since then the Reflolux 11 has been replaced by the Boehringer Accutrend. Although this instrument was found to be reliable when used correctly.l in practice
E B, Duly, T R, Trinick, P, Grimason
openaire +2 more sources
The Effect of Haemolysis on Blood Glucose Meter Measurement
Diabetic Medicine, 1995A study was performed to assess the effect of varying degrees of sample haemolysis on the measurement of blood glucose by the Accutrend, Companion 2, ExacTech, Glucometer II, Glucometer 4, One Touch II, and Reflolux II blood glucose meters. Fresh venous blood was sonicated to induce complete haemolysis and then added in increasing proportions to ...
E S, Kilpatrick +2 more
openaire +2 more sources
Self-Monitoring of Blood Glucose Without a Meter
Diabetes Care, 1981We studied the reliability of the Chemstrip system in the self-monitoring of blood glucose by diabetic patients. A total of 453 blood glucose values obtained by 38 diabetic patients using Chemstrip were compared with the glucose values of the same blood samples measured with a conventional laboratory method.
K, Birch +3 more
openaire +2 more sources
Evaluation of a blood glucose meter in a tropical environment
Transactions of the Royal Society of Tropical Medicine and Hygiene, 1986Les resultats montrent que le glucometre est un instrument utile pour la mesure du glucose sanguin en zone tropicale. Dans des pays comme la Tanzanie ces appareils sont d'une grande utilite dans les petits laboratoires des zones ...
A H, Klokke, A B, Swai, D G, McLarty
openaire +2 more sources
ExacTech Blood Glucose Meter Clinical Trial
Prehospital and Disaster Medicine, 1993AbstractIntroduction:Current prehospital protocols for the management of patients with altered mental status include the empiric administration of hypertonic glucose, naloxone, and thiamine. The injudicious use of 50% dextrose (D50W) may result in hyperosmolarity, a worsening of hypokalemia, and unwarranted additional health-care costs for the patient.
E A, Bartkus +3 more
openaire +2 more sources
PERFORMANCE OF BLOOD-GLUCOSE METERS
The Lancet, 1979L J, Borthwick, I S, Ross
openaire +4 more sources