Results 31 to 40 of about 3,019,588 (285)
Avaliou-se a precisão analítica e clínica de dois sensores portáteis para mensuração da glicemia em cães. Os valores da mensuração da glicemia obtidos com os sensores foram comparados com aqueles obtidos pelo método padrão da glicose oxidase, por meio da
K. Bluwol +4 more
doaj +1 more source
Background Self-monitoring of blood glucose (SMBG) has been shown to reduce hemoglobin A1C (HbA1C). Accordingly, guidelines recommend SMBG up to 4–10 times daily for adults with type 2 diabetes (T2DM) on insulin.
Alex R. Montero +5 more
doaj +1 more source
History and Evolution of Capillary Glucose Monitoring
Monitoring of blood glucose levels is an inevitable part of diabetes management. The last decade was marked by path-breaking and transformational changes in diabetes technologies that ushered in the introduction of a wide spectrum of glucose monitoring ...
Jothydev Kesavadev +9 more
doaj +1 more source
Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs [PDF]
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern.
Sina Jahan +3 more
doaj +1 more source
In vivo blood glucose quantification using Raman spectroscopy. [PDF]
We here propose a novel Raman spectroscopy method that permits the noninvasive measurement of blood glucose concentration. To reduce the effects of the strong background signals produced by surrounding tissue and to obtain the fingerprint Raman lines ...
Jingwei Shao +6 more
doaj +1 more source
Impairment of carbohydrate metabolism in children and adolescents with obesity
Obesity is one of the socially significant diseases of our time and is a generally recognized risk factor for the development of carbohydrate metabolism disorders, including type 2 diabetes mellitus (DM), the prevalence of which in the pediatric ...
A. V. Vitebskaya, A. V. Popovich
doaj +1 more source
The accuracy of self monitoring blood glucose meter systems in Kampala Uganda [PDF]
Background: Many blood glucose self-monitoring systems are privately and publicly used by people in Uganda and technical and human errors may occur during their operation.
Sabuni, S. +4 more
core +1 more source
Validation of Point-of-Care Glucose Testing for Diagnosis of Type 2 Diabetes
Point-of-care (POC) glucose technology is currently considered to be insufficiently accurate for the diagnosis of diabetes. The objective of this study was to investigate the diagnostic accuracy of an innovative, interference-resistant POC glucose meter (
Marijana Vučić Lovrenčić +4 more
doaj +1 more source
Role of blood glucose self-monitoring in management of gestational diabetes mellitus
Gestational diabetes mellitus (GDM) is a disorder characterized by hyperglycemia first recognized during pregnancy that does not meet the criteria of manifest diabetes mellitus (DM).
Galina A. Batrak, Nataliya V. Batrak
doaj +1 more source
Self-monitoring of diabetes mellitus: why Contour TC?
Self-monitoring of blood glucose remains the cornerstone in the treatment of diabetes. The primary aim of diabetes treatment is target level of glycemia, which can not be achieved without effective self-moniroting with a glucose meter.
L. Y. Morgunov
doaj +1 more source

