Results 171 to 180 of about 945,096 (227)
Some of the next articles are maybe not open access.
Bone scintigraphy in hypervitaminosis A
American Journal of Roentgenology, 1985The diagnosis of vitamin A intoxification may be difficult at the time of initial presentation. The radionuclide bone scan in cases of vitamin A toxicity may serve as a more sensitive indicator of the presence of this disease than radiographs in the initial evaluation and follow-up of patients with skeletal involvement.
J H, Miller, I I, Hayon
openaire +2 more sources
Clinical Nuclear Medicine, 1993
Several physiologic and pathologic conditions demonstrating extraosseous localization of bone scanning agents have been described, including metastatic calcification of the soft tissues secondary to metabolic disorders, malignancies, and chronic renal failure.
S, Murthy +4 more
openaire +2 more sources
Several physiologic and pathologic conditions demonstrating extraosseous localization of bone scanning agents have been described, including metastatic calcification of the soft tissues secondary to metabolic disorders, malignancies, and chronic renal failure.
S, Murthy +4 more
openaire +2 more sources
Bone Scintigraphy in Cleidocranial Dysplasia
Clinical Nuclear Medicine, 2004Cleidocranial dysplasia (CLCD) is an autosomal-dominant disorder. There is altered bone formation with clavicular hypoplasia or agenesis with a narrow thorax, causing approximation of the shoulders in front of the chest occurring with delayed ossification of the skull, excessively large fontanelles, and delayed closure of the sutures.
Alper, Fatih +7 more
openaire +3 more sources
Bone scintigraphy in metabolic bone disease
Seminars in Nuclear Medicine, 1997The bone scan has well-recognized appearances in metabolic bone diseases, with its main clinical value found in focal conditions or the focal complications of disease. In clinical practice, the bone scan is most widely used to detect fractures in osteoporosis and pseudofractures in osteomalacia and to evaluate Paget's disease.
P J, Ryan, I, Fogelman
openaire +2 more sources
Bowel visualization in bone scintigraphy
Seminars in Nuclear Medicine, 1987Ce phenomene etait du a la presence d'une ureterosigmoidostimie pratiquee apres un traumatisme 11 ans ...
L, Ackerman +4 more
openaire +2 more sources
Bone Scintigraphy in Perthes Disease
Journal of Pediatric Orthopaedics, 1983After intravenous injection of 99mTc methyldiphosphonate, 190 hip bone scans were performed on 103 children. In 64 children with Perthes disease, 61 of 71 hips (86%) showed abnormal scintigraphy. There were no false positives. In other hip disorders, the scan was never considered to simulate Perthes disease.
H, Bensahel +3 more
openaire +2 more sources
Bone Scintigraphy in a Patient With Polymyositis
Clinical Nuclear Medicine, 1995A 81-year-old woman who underwent resection of a primary recto-sigmoid adenocarcinoma 14 months previously had musculoskeletal pain and weakness of the proximal limb muscles, facial erythema, and weight loss for 1 month. The bone scan showed intense and heterogeneous uptake in the proximal limb muscles. Because no other scintigraphic abnormalities were
A, Cuartero-Plaza +3 more
openaire +2 more sources
Bone Scintigraphy of Madura Foot
Clinical Nuclear Medicine, 1999Three-phase Tc-99m MDP bone imaging of the feet was performed in a 69-year-old woman, a retired missionary who had worked in India and Africa. She was followed in the tropical disease clinic at our institution for a draining sinus from the dorsum of her right foot, which was cultured and found to be positive for Madurella mycetomatis.
S N, Ganguli, M, Hershkop
openaire +2 more sources
TECHNICAL ASPECTS OF BONE SCINTIGRAPHY
Radiologic Clinics of North America, 1993Optimal bone scintigraphy is obtained by using a current generation gamma camera with a high-resolution collimator, minimizing the patient-to-collimator distance, using scatter reduction techniques where possible, and obtaining a 500,000 to 1 million count image for 40-cm field of view camera. Hard copy images from an analog or digital formatter should
M L, Brown +3 more
openaire +2 more sources
Serendipity and Bone Scintigraphy
Clinical Nuclear Medicine, 1985M G, Velchik +3 more
openaire +2 more sources

