In this work, we demonstrated a robust 2D MoS2 based iontronic memtransistor of planar architecture operated under the influence of an electrical double layer with versatile performance and applications, including pinched hysteresis nature of transfer curve, analogue channel conductance tuning, low‐voltage operation, logic‐gate operation, classical ...
Puranjay Saha +2 more
wiley +1 more source
Wirelessly Interrogated, Implantable Capacitive MEMS Sensors for Continuous Intraocular Pressure Monitoring. [PDF]
Li L, Zaman A, Ayyala R, Wang J.
europepmc +1 more source
An ultrafast (2‐minute), gas‐free chemical pre‐sodiation strategy using Na‐benzophenone is developed to compensate for initial sodium loss in calcium vanadate (CaV8O20). Driven by the Ca2+ ‘spectator effect’, the framework enables highly reversible, quasi‐zero‐strain solid‐solution sodium storage, explicitly bypassing destructive conversion reactions ...
Neetu Bansal +7 more
wiley +1 more source
A Flexible Capacitive Pressure Sensor with Broad-Range High Sensitivity Based on 3D Porous Ionogel for Wearable Health Monitoring. [PDF]
Chen Y, Xie X, Wang Y, Liu D.
europepmc +1 more source
Transparent Topological Meta‐Diplexer via Tightly Confined Valley Surface States
An optically transparent topological metasurface supporting tightly confined valley surface states enables robust and flexible wave routing in an ultrathin platform. A compact transparent meta‐diplexer with spatially and spectrally separated channels is realized, while communication experiments verify high‐fidelity signal transmission, opening new ...
Sijie Li +5 more
wiley +1 more source
Capacitance-Based Characterization of Air-Void Distribution in Asphalt Mixtures Using a Saturated Reference Field. [PDF]
Hu X, Dong Q, Shi B, Yao K, Liu Z.
europepmc +1 more source
3D-Printed Metamaterial-Based Soft Sensors: Materials, Design, and Fabrications. [PDF]
Park S +8 more
europepmc +1 more source
Electronically switchable band tuned filtering power divider for Sub-6 GHz applications. [PDF]
Mathur R, Choudhary DK.
europepmc +1 more source
A Wireless, Passive Multimodal Wearable Sensor With Decoupled Sensing Capabilities. [PDF]
Han W +8 more
europepmc +1 more source
A Biosafety Comparison Between Capacitive and Inductive Coupling in Biomedical Implants
peer reviewedThis letter investigates the link efficiencies and ensuing biohazards when capacitive versus inductive coupling is used to power biomedical implants electromagnetically.
Jean-Michel Redoute, Mehmet Raşit Yüce
exaly +2 more sources

