Results 91 to 100 of about 57,859 (256)
This mixed methods study aimed to: (i) identify treatment expectations held by individuals with a ventricular assist device (VAD), (ii) assess the extent to which these expectations have been met, and (iii) examine how treatment expectations relate to VAD‐specific health‐related quality of life (HRQoL) ABSTRACT Objectives Treatment expectations ...
Simon Felix Zerth +10 more
wiley +1 more source
Blade shapes (leading‐edge geometry and thickness) in rotodynamic blood pumps were systematically evaluated. Thinner blades improve pump efficiency by reducing blockage effects, while neither blade thickness nor leading‐edge geometry shows clear hemocompatibility benefits. Overall, blade shape has a limited impact on hemocompatibility, indicating it is
Benjamin Torner +7 more
wiley +1 more source
Consensus surrounding the management of VA ECMO and left ventricular mechanical unloading for cardiogenic shock (CS) is limited. We thus conducted a national survey of practice patterns in the treatment of CS to characterize such variability, finding large heterogeneity in CS diagnosis, VA ECMO initiation, and LVMU strategies.
Dustin M. Anderson‐Bell +16 more
wiley +1 more source
This study is a comprehensive post‐market analysis of the Xenios console and XLung kit 230 preconfigured ECMO tubing set in post‐cardiotomy applications. The performance of this device was evaluated and demonstrated in all key clinical areas, with an adequate safety profile.
Luca Conci +9 more
wiley +1 more source
Reuse, Reduce, Recycle: the 21st century Mantra
A. Manickavasagam +4 more
doaj +1 more source
Analysis of 4928 normothermic machine perfusion liver transplants reveals that recipient factors, particularly MELD ≥ 35, surgical complexity, ICU status, and functional impairment are stronger predictors of graft failure than donor characteristics, emphasizing the continued importance of clinical judgment in patient selection.
Lauren E. Matevish +9 more
wiley +1 more source
This study utilized an extensive optimization involving n = 540 design of experiments to produce a superior drainage cannula design. Compared to the clinically used Maquet model, our optimized design demonstrated reduced blood stagnation volumes, increased cannula tip velocities, and higher upper body drainage, potentially minimizing risk of thrombosis
Avishka Wickramarachchi +3 more
wiley +1 more source
Transesophageal Electrophysiological Study in Management of Pediatric tachyarrhythmias
A. Manickavasagam +4 more
doaj +1 more source
Preventable geometric failure modes, such as outflow graft kinking and inflow malposition, frequently cause HeartMate 3 dysfunction. This study identifies these complications as key drivers of device‐related morbidity, highlighting the importance of optimized surgical positioning to ensure long‐term device performance and improved clinical outcomes ...
Ali Saad Merzah +17 more
wiley +1 more source
Remote monitoring (RM) of cardiac implantable electronic devices generates large volumes of data that must be reviewed using vendor-specific platforms, creating a growing clinical workload.
Benjamin Sacristan +6 more
doaj +1 more source