Results 121 to 130 of about 1,007,387 (146)
Some of the next articles are maybe not open access.
Voluntary cardio-respiratory synchronization: hardware and software development and evaluation
2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2005Voluntary cardio-respiratory synchronization (VCRS) is a technique where an individual's breathing is voluntarily phase locked with his/her heart beat. A signal is generated (tone or light) from the ECG that is used to pace the breath with a fixed number of heart beats for inspiration and expiration.
R.P. Patterson +3 more
openaire +1 more source
Physiological Measurement, 2003
Voluntary cardio-respiratory synchronization (VCRS) was used to investigate heart rate and blood pressure changes in the supine position in 21 subjects. VCRS involves a breathing pattern that is synchronized with the cardiac cycle. The signals to inhale and exhale are derived from the ECG.
Lynne I, Mason, Robert P, Patterson
openaire +2 more sources
Voluntary cardio-respiratory synchronization (VCRS) was used to investigate heart rate and blood pressure changes in the supine position in 21 subjects. VCRS involves a breathing pattern that is synchronized with the cardiac cycle. The signals to inhale and exhale are derived from the ECG.
Lynne I, Mason, Robert P, Patterson
openaire +2 more sources
Physiological Measurement, 2017
Abstract Objective: Phase synchronization between two weakly coupled oscillators occurs in many natural systems. Since it is difficult to unambiguously detect such synchronization in experimental data, several methods have been proposed for this purpose.
Kuhnhold, Anja +6 more
openaire +3 more sources
Abstract Objective: Phase synchronization between two weakly coupled oscillators occurs in many natural systems. Since it is difficult to unambiguously detect such synchronization in experimental data, several methods have been proposed for this purpose.
Kuhnhold, Anja +6 more
openaire +3 more sources
Cardio‐respiratory synchronization and myocardial function in hypoxic carp, Cyprinus carpio L.
Journal of Fish Biology, 1991Moderate hypoxia (Pio2, = 50 mmHg) caused tachycardia in carp, Cyprinus curpio Linnaeus, whereas severe hypoxia (Pio2, from 30 to 5 mmHg) coincided with bradycardia accompanied by alterations of the waveforms of the electrocardiogram. A cardio respiratory synchronization developed during hypoxia and was maintained during bradycardia.
M. L. Glass +4 more
openaire +1 more source
Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society, 2003
The respiratory variations of stroke volume (SV), R-R interval and ventricle filling time were studied in supine and sitting conditions. The tests were performed under VCRS on ten male subjects. Impedance cardiography (ZCG) was used with band electrodes to measure SV. SV increased during inspiration and decreased during expiration.
L. Wang, R.P. Patterson, S.B. Raza
openaire +1 more source
The respiratory variations of stroke volume (SV), R-R interval and ventricle filling time were studied in supine and sitting conditions. The tests were performed under VCRS on ten male subjects. Impedance cardiography (ZCG) was used with band electrodes to measure SV. SV increased during inspiration and decreased during expiration.
L. Wang, R.P. Patterson, S.B. Raza
openaire +1 more source
Zhurnal vysshei nervnoi deiatelnosti imeni I P Pavlova, 2003
Human breathing and cardiac rhythms become synchronized during voluntary respiration of a subject with the rate higher than the initial cardiac rate. This phenomenon is observed during driving of the breathing rhythm with rhythmical flashes of a photostimulator lamp.
E G, Potiagaĭlo, V M, Polrovskiĭ
openaire +1 more source
Human breathing and cardiac rhythms become synchronized during voluntary respiration of a subject with the rate higher than the initial cardiac rate. This phenomenon is observed during driving of the breathing rhythm with rhythmical flashes of a photostimulator lamp.
E G, Potiagaĭlo, V M, Polrovskiĭ
openaire +1 more source
Cardio-respiratory monitor with synchronization capabilities
2018Cardiopathies are some of the most common causes of death worldwide and therefore cardiac imaging is one of the most important studies that can be performed in the diagnostic process. However, not only does cardiac imaging have special requirements when it comes to the equipment used such as spatial and temporal resolution, but final image quality and ...
openaire +2 more sources
Steps towards evaluating cardio-respiratory synchronicity in protective ventilation
Journal of Critical Care, 2013Jan F. Kraemer +2 more
openaire +1 more source

