Results 201 to 210 of about 295,883 (252)
Calcium-Triggered PuMYB44-PuERF118 Cascade Activates <i>PuFAD8</i> to Promote Aroma Biosynthesis in Pear Fruit. [PDF]
Wang X +8 more
europepmc +1 more source
The health effects of extreme heat. [PDF]
Lahri S.
europepmc +1 more source
Development and Validation of an ELISA to Detect Antibody to Onchocerca volvulus Infection Using Mammalian Expressed Recombinant Ov16. [PDF]
Ossai S +6 more
europepmc +1 more source
Analysis of compression–absorption cascade refrigeration cycles
Abstract In this study, LiBr–H2O pair was used for the first time for absorption section of compression–absorption cascade refrigeration cycles. These cycles were analyzed theoretically and compared with using different refrigerants in the compression and absorption sections.
Canan Cimsit, Ilhan Tekin Öztürk
exaly +4 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Compression–absorption cascade refrigeration system
Applied Thermal Engineering, 2006This paper describes the study carried out to analyse a refrigeration system in cascade with a compression system at the low temperature stage and an absorption system at the high temperature stage to generate cooling at low temperatures, as well as the possibility of powering it by means of a cogeneration system.
Jaime Sieres, José Fernández-Seara
exaly +2 more sources
Theory of cascade refrigeration
AIP Conference Proceedings, 2012The maximum difference between the warm and cold temperature of a refrigeration cycle is limited by properties of the refrigerant and/or losses associated with the transport of the refrigerant. For larger temperature differences, one has to arrange several refrigeration cycles “above” each other, each cycle spanning a certain temperature difference ...
openaire +1 more source
Performance Experiment of Natural Refrigerant Cascaded Refrigeration System
Advanced Materials Research, 2011In this paper, the performances of natural refrigerant R290/CO2 cascaded refrigeration system using R290 as high temperature cycle refrigerant and CO2 as low temperature cycle refrigerant were investigated experimentally. The test results show that both CO2 compressor and R290 compressor start up stably and present good running performance.
Jing Hong Ning, Sheng Chun Liu
openaire +1 more source
Analysis of Cascade Vapour Refrigeration System with Various Refrigerants
Materials Today: Proceedings, 2019Abstract In this paper report the performance analysis of different refrigerants couples in cascade refrigeration system. Refrigerants such as R134a/R23, R410A/R23 and R404A/R170 have been successfully analyzed in the superheating and sub cooling range of 10 °C and 5 °C respectively. The variation in condenser temperature was from 30 to 50 °C in high
K. Logesh +4 more
openaire +1 more source
Cascade Refrigeration System: R404a-R23 Refrigerant
Asian Journal of Electrical Sciences, 2017This study is presented a cascade refrigeration system using as refrigerant (R23) in low-temperature circuit and R404a in high-temperature circuit. The operating parameters considered in this paper include superheating, condensing, evaporating, and sub cooling temperatures in the refrigerant (R404a) high temperature circuit and in the refrigerant (R23))
openaire +1 more source
Refrigerant conversion of auto-refrigerating cascade (ARC) systems
International Journal of Refrigeration, 1997Abstract This paper describes converting Auto-Refrigerating Cascade (ARC) ultra-low temperature systems from a multicomponent zeotropic working fluid containing CFS to a CFC-free mixture. The differences between azeotropes, mixtures and blends with minimal glides used in conventional refrigeration systems and the steep glide (wide span) zeotropes ...
openaire +1 more source