Results 11 to 20 of about 1,630 (220)
Cooling systems have been widely studied over the past few years, but there are little researches on cascade cooling system containing different cooling methods. Cascade cooling system is suitable for the hot stream cooling process with large temperature
Youlei Wang, Yufei Wang, Xiao Feng
doaj +1 more source
The cooling capacity needed by ultra-low temperature apparatus cannot be reached economically with a single vapor compression refrigeration cycle due to the constraint of the high compressor pressure ratio.
Zhenzhen Liu +3 more
doaj +1 more source
Performance of an Air Refrigeration System for the Cold Storage of Vaccines
The performance and feasibility of the air refrigeration system applied to vaccine cold storage were explored and compared with a cascade refrigeration system based on characteristics of safety and environmental protection, local availability of the ...
Wang Qin +4 more
doaj
More and more applications, such as natural gas liquefaction, LNG reliquefaction, whole body cryotherapy and cryopreservation, require cooling in the temperature range from 110 to 150 K.
Zbigniew Rogala, Adrian Kwiatkowski
doaj +1 more source
Optimum parametric analysis based on thermodynamic modeling of a compression absorption cascade refr
In the present study a cascade refrigeration system (CRS) comprising of a vapor compression refrigeration (VCR) system in the low temperature (LT) stage and a single stage vapor absorption refrigeration (VAR) system in high temperature (HT) stage is ...
Naushad ANSARI +3 more
doaj +1 more source
Cascade refrigeration systems are preferred in applications where low temperature cooling is required, such as in some special industrial and laboratory applications.
Meltem Koşan
doaj +1 more source
A conventional vapor compression refrigeration system (VCRS) cascaded with a heat-assisted ejector refrigeration system (ERS) has been experimentally analyzed. Cascading allows the VCRS to operate at lower condenser temperatures and thus achieve a higher coefficient of performance. In this cascaded system, the condenser of the vapor compression system
Vikas Kumar +4 more
openaire +1 more source
A simple vapor-compression refrigeration system becomes ineffective and inefficient as it consumes a huge energy supply when operating between large temperature differences. Moreover, the recent Kigali amendment has raised a concern about phasing out some hydrofluorocarbon refrigerants due to their impact on the environment.
G. Shanmugasundar +3 more
openaire +2 more sources
Performance Experiment of R290/CO2 Cascade Refrigeration System
Performance experiments of R290/CO2 cascade refrigeration system were conducted. The performance of a cascade refrigeration system having a high temperature cycle using R290 as refrigerant and a CO2 based low temperature cycle was compared with that of a
宁静红, 李惠宇, 彭苗
doaj +2 more sources
Thermodynamic Analysis of a Cascade Refrigeration System
There is a need for cooling by using the waste heat energy in food industry. Absorption cycles can be driven by waste thermal, geothermal, solar or industrial processes energies. In this study, cascade refrigeration system is thermodynamically modeled, and analyzed by using first law of thermodynamics, and exergy method.
openaire +1 more source