Results 251 to 260 of about 2,833,308 (337)

Patient‐Reported Feedback Suggests an Alternative Sweet Spot for Deep Brain Stimulation Programming in Essential Tremor

open access: yesMovement Disorders, EarlyView.
(1) To sample subjective patient rating using the Visual Analogue Scale (VAS), random stimulation parameters were presented to the study subjects. (2) Next, corresponding volumes of tissue activated (VTA) were generated and paired with VAS values.
Sophia Peschke   +9 more
wiley   +1 more source

Coaxial Dipole Array With Switching Transmit Sensitivities for Ultrahigh Field MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To investigate dipole antennas with electronically switchable transmit field patterns to improve flip angle homogeneity in ultra‐high field MRI. Methods Reconfigurable dipole elements that could produce two distinct electronically switchable B1+$$ {B}_1^{+} $$ field profiles were conceptualized and constructed. Eight such elements were
Dario Bosch   +5 more
wiley   +1 more source

Quantitative Comparison of Multi‐Echo Spin Echo and Multi‐Echo Gradient Echo Myelin Water Imaging in a Panel of Mbp Enhancer‐Edited Mouse Lines

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate the correspondence between myelin water fraction (MWF) estimates derived from multi‐echo spin echo (MESE) and multi‐echo gradient echo (MGRE) imaging in fixed mouse brain tissue, using a panel of myelin basic protein (Mbp) enhancer‐edited mouse lines exhibiting graded hypomyelination.
Vladimir Grouza   +11 more
wiley   +1 more source

Complementary Sensitivity of Fixed‐Time and Fixed‐Oscillation Regimes to Exchange and Structural Disorder in the Human Brain Revealed Using Oscillating‐Gradient Diffusion MRI With Ultra‐Strong Gradients

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Oscillating‐gradient spin‐echo (OGSE) diffusion MRI probes cell geometry and membrane integrity through the frequency‐dependence of kurtosis, but prior studies have reported inconsistent findings depending on how frequency is varied. We compared frequency‐dependent kurtosis in the human brain under two regimes: varying frequency with ...
Dongsuk Sung   +8 more
wiley   +1 more source

Continuous caudal block : role in paediatrics

open access: yesIndian Journal of Anaesthesia, 2003
Neha Shah   +3 more
doaj  

Respiration Can Trigger Cerebrovascular Reactivity: A Novel Method to Quantify Cerebrovascular Resistance Dynamics Using Real‐Time Phase‐Contrast MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To directly quantify respiration‐driven cerebrovascular resistance dynamics (CRD) using a gas‐free MRI framework based on the internal‐to‐external artery carotid flow ratio (ratio_Q). Theory and Methods Two independent datasets (n = 10 and n = 17) were used to evaluate repeatability and to compare breathing conditions.
Pan Liu   +5 more
wiley   +1 more source

Double Asymmetric Spin Echo EPI (dASE‐EPI) Enables fMRI of the Entire Rat Brain at 9.4 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Development and evaluation of a double asymmetric spin echo planar imaging (dASE‐EPI) sequence to balance sensitivity to blood oxygenation level‐dependent (BOLD) contrast with mitigation of susceptibility‐induced intravoxel spin dephasing in ultra high‐field rodent brain imaging.
Kyle A. Johnson   +2 more
wiley   +1 more source

Medical imaging in the canine stifle [PDF]

open access: yes, 2012
Gielen, Ingrid   +2 more
core  

Home - About - Disclaimer - Privacy