Results 91 to 100 of about 815,847 (240)
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan+3 more
wiley +1 more source
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka+6 more
wiley +1 more source
Abstract Purpose The Bravos v1.2 control software introduces a ring applicator component type (ACT) with channel length verification to address geometric characteristics and dosimetric discrepancies caused by source positioning inaccuracies. This study aims to commission the ring applicator and investigate the new ring ACT in Bravos 1.2.
Xiuxiu He+4 more
wiley +1 more source
The Benefits of Human Resource Certification: A Critical Analysis and Multi-Level Framework for Research [PDF]
Despite the huge success of marketing certification to human resources (HR) professionals, does it benefit individuals, employers, and the field of HR?
Herman Aguinis, Mark L. Lengnick-Hall
core
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan+6 more
wiley +1 more source
Consumer confusion and multiple equilibria [PDF]
This paper focuses on consumer confusion when firms may choose between credible and non-credible certification systems for signalling quality. It is shown that the presence of confused consumers leads to the emergence of multiple stable equilibria, in ...
Stéphan Marette
core
Abstract Purpose This study quantitatively evaluates bladder changes and their dosimetric impact during the on‐couch adaptive process on a commercial CBCT‐based online adaptive radiotherapy (CT‐gART) platform. Methods Data from 183 fractions of ten patients receiving online ART for pelvic cancers were analyzed retrospectively.
Ingrid Valencia Lozano+7 more
wiley +1 more source
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi+3 more
wiley +1 more source
Abstract Purpose This work introduces BreastWatch, a Varian Eclipse script tool designed to help medical physicists, dosimetrists, and radiation oncologists easily inspect and improve External Beam Breast Treatment (EBBT) plans using automatic evaluation of protocol dose‐constraints enhanced by a Community‐Based approach.
Stefano Agostinelli+8 more
wiley +1 more source