A segmented neutron detector based on Silicon-PIN photodiodes using neutron-proton converters [PDF]
A segmented neutron detection system based on windowless silicon-PIN photodiodes has been designed and tested with various hydrogen rich converter materials.
Bayrak Ahmet +3 more
doaj +1 more source
Implementation of Reading Electronics of Silicone Photomultipliers on the Array Chip МН2ХА030
The implementation of a charge-sensitive amplifier (CSA) based on the МН2ХА030 array chip (AC) with an adjustable conversion factor for processing signals of silicone photomultipliers (SPM) is considered.
O. V. Dvornikov +5 more
doaj +1 more source
Characterization of a Low Noise and Low Background Charge Sensitive Amplifier for the Readout of Germanium Detectors [PDF]
The observation of neutrinoless double beta decay would have major implications in the understanding of the origin of the matter in the universe. Given zero electric charge and no colour, they may be Majorana particles, i.e. their own antiparticles.
Butta, D. +9 more
core +1 more source
Charge Sensitive Amplifier (CSA) in cold gas of Liquid Argon (LAr) Time Projection Chamber (TPC) [PDF]
International audienceThis paper presents our work on a 8-channel low noise Front-End electronic coupled to a Liquid Argon (LAr) TPC (Time Projection Chamber).
E Bechetoille +5 more
core +1 more source
Novel Charge Sensitive Amplifier Design Methodology suitable for Large Detector Capacitance Applications [PDF]
Current mode charge sensitive amplifier (CSA) topology and related methodology for use as pre-amplification block in radiation detection read out front end IC systems is proposed1. It is based on the use of a suitably configured current conveyor topology
Gerard Sarrabayrouse b,c and +3 more
core +1 more source
A Charge-Sensitive Amplifier Associated with APD or PMT for Positron Emission Tomography Scanners [PDF]
to be presented at the 32nd International Convention MIPRO (Microeectronics, Electronics, and Electronic Technology (MEET)), Opatija, Croatia, May 25-29 2009International audienceWe present a Charge-Sensitive Amplifier (CSA) to be coupled with a 511-KeV ...
Russo, P. +6 more
core +1 more source
Transient surface photovoltage spectroscopy of diamond
Contactless and highly sensitive probing of electronic transitions in diamond over a wide spectral range from near infrared to deep ultraviolet is still challenging.
Th. Dittrich
doaj +1 more source
Circuit design of VLSI for microelectronic coordinate-sensitive detector for material element analysis [PDF]
There has been designed, manufactured and tested a VLSI providing as a part of the microelectronic coordinate-sensitive detector the simultaneous elemental analysis of all the principles of the substance.
Sidorenko V. P. +2 more
doaj +2 more sources
An unexpected alternative interaction site for ethyl viologen was identified in formate dehydrogenase 1 from Methylorubrum extorquens. Combined mutagenesis, kinetic analysis, and docking revealed that aromatic residues near an iron–sulfur cluster enable flavin mononucleotide‐independent electron transfer, offering a framework for engineering improved ...
Eleni G. Poloniataki, Yong Hwan Kim
wiley +1 more source
Comprehensive Noise Modeling of Piezoelectric Charge Accelerometer with Signal Conditioning Circuit
This paper reports on noise modeling of a piezoelectric charge accelerometer with a signal conditioning circuit. The charge output is converted into voltage and amplified using a JFET operational amplifier that has high input resistance and low noise ...
Ghulam Ali, Faisal Mohd-Yasin
doaj +1 more source

