Results 1 to 10 of about 15,247 (308)

Investigation on the fault monitoring of high-voltage circuit breaker using improved deep learning. [PDF]

open access: yesPLoS ONE, 2023
Mechanical faults are the main causes of abnormal opening, refusal operation, or malfunction of high-voltage circuit breakers. Accurately assessing the operational condition of high-voltage circuit breakers and delivering fault evaluations is essential ...
Hao Chen   +5 more
doaj   +2 more sources

A current‐limiting DC circuit breaker with power flow control capability

open access: goldIET Generation, Transmission & Distribution, 2022
Power flow controller (PFC), fault current limiter (FCL) and DC circuit breaker (DCCB) are important equipment in the DC grid. There are a large number of power electronic components in these equipment, resulting in high cost.
Shimin Xue   +5 more
doaj   +2 more sources

Optimal circuit breaker allocation strategy in DC transmission-connected systems [PDF]

open access: yesScientific Reports
The purpose of this study is to provide data for the best possible circuit breaker allocation in power grids with HVDC transmission while taking circuit breaker failure into account. The lack of a suitable selection of HVDC circuit breakers is one of the
Beopsoo Kim, Insu Kim
doaj   +2 more sources

Topology and control of a novel hybrid HVDC circuit breaker with self-powered capability

open access: yesEnergy Reports, 2022
Power supply for IGBT drive circuit of HVDC circuit breaker is a great challenge in practical engineering. At present, most of the HVDC circuit breakers rely on external power sources. This paper proposes a self-powered hybrid HVDC circuit breaker.
Huangqing Xiao   +4 more
doaj   +1 more source

A Self-commutated HVDC Circuit Breaker Based on Forced Zero Crossing Technology

open access: yesZhongguo dianli, 2021
In order to improve the breaking capacity of Hybrid DC circuit breaker and reduce the harm of DC short circuit fault to the system, we proposed a self-commutated HVDC circuit breaker based on forced zero crossing technology.
Guoqing LI   +3 more
doaj   +1 more source

Restrike characteristics of vacuum circuit breaker in its opening process under DC voltage

open access: yesIET Science, Measurement & Technology, 2023
The restrike of vacuum circuit breaker during the breaking process causes overvoltage and intensifies the insulation deterioration of high‐voltage equipment. To solve this problem, the vacuum breaker aging test method and the restrike characteristics are
Jixing Sun   +8 more
doaj   +1 more source

Development of four‐terminal DC circuit breaker based on commutating path multiplexing

open access: yesIET Generation, Transmission & Distribution, 2023
Multi‐terminal flexible DC power grid plays an important role in large‐scale new energy integration, which usually requires the installation of multi‐terminal DC circuit breaker (MTCB) at the intersection of multiple DC lines. At present, the research on
Zhizheng Gan   +9 more
doaj   +1 more source

Influence of capacitor-buffered hybrid DC circuit breaker on bipolar short circuit fault of three-terminal MMC-HVDC transmission system

open access: yesEnergy Reports, 2020
The flexible DC transmission system needs a DC circuit breaker to remove and isolate the bipolar short-circuit fault to prevent the excessive short-circuit current from damaging the DC transmission system.
Can Ding   +3 more
doaj   +1 more source

Insulation Resistance and Tracking Index of Circuit Breaker According to the Accelerated Aging Test

open access: yesIEEE Access, 2023
This study examined insulation resistance and tracking index characteristics through the accelerated aging test of low-voltage circuit breakers. The leakage current was found to be influenced by external factors rather than the internal structure ...
Sin-Dong Kang, Jae-Ho Kim
doaj   +1 more source

Introduction of an Auxiliary Breaker into the Generator-Transformer Block for Energy Saving in Open Switchgear Circuits of Power Plants

open access: yesИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика, 2023
A need in finding of new ways of energy saving at open switchgears of power plants is substantiated. In order to increase energy saving efficiency, an auxiliary breaker is suggested to be inserted between a transformer of a block and its two high-voltage
A. S. Barukin   +3 more
doaj   +1 more source