Results 91 to 100 of about 39,446 (240)

A Survey of Hybrid Circuit Breakers: Component-Level Insights to System-Wide Integration

open access: yesIEEE Open Journal of Power Electronics
This survey provides a comprehensive review of hybrid circuit breakers and their applications in 1 kV to 800 kV, both alternating current and direct current systems.
Yuchen He   +3 more
doaj   +1 more source

Circuit Breaker

open access: yesInternational Journal of Innovative Science and Research Technology (IJISRT)
In the realm of microservices architecture, ensuring reliability and resilience is paramount due to the distributed nature and interdependencies of services. A key pattern employed to enhance system robustness is the circuit breaker. When a microservice experiences failures, the circuit breaker pattern detects these faults and transitions between three
openaire   +1 more source

Logic-controlled solid state switchgear for 270 volts dc [PDF]

open access: yes
A feasibility study to design and demonstrate solid state switchgear in the form of circuit breakers and a power transfer switch is described. The switchgear operates on a nominal 270 V dc circuit and controls power to a load of up to 15 amperes.
Buchanan, E. E., Jr.   +2 more
core   +1 more source

Protection strategy for multi-terminal DC networks with fault current blocking capability of converters [PDF]

open access: yes, 2017
High voltage dc networks are a promising technology to flexibly transmit power over long distances. However, dc grid protection is still a major challenge. DC fault clearance can be mainly achieved with three devices. These are ac circuit breakers (ACCBs)
Adamczyk, A.   +5 more
core   +1 more source

Arc Resistance Enhancement of Converter Transformer Tank Through Structural Improvements: Simulation and Experimental Validation

open access: yesHigh Voltage, EarlyView.
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang   +5 more
wiley   +1 more source

Fault Diagnosis of High-Voltage Circuit Breakers Using Mechanism Action Time and Hybrid Classifier

open access: yesIEEE Access, 2019
Accurate fault diagnosis of high-voltage circuit breakers is crucial for the safety of power grids. Mechanism action time, though can reflect the state of high-voltage circuit breakers, is usually difficult to obtain, as multiple sensors are required for
Shuting Wan, Lei Chen
doaj   +1 more source

Caregivers' perspectives of support needs for adolescents with fetal alcohol spectrum disorder

open access: yesChildren &Society, EarlyView.
Abstract Research focused on fetal alcohol spectrum disorder (FASD) is often deficit‐focused, limiting a holistic understanding of individuals' support needs. Families of adolescents with FASD also struggle to access appropriate services. Using semi‐structured interviews, the current study explored the perspectives of seven caregivers of adolescents ...
Kelly Skorka   +4 more
wiley   +1 more source

Protection and post-fault recovery of large HVDC networks using partitioning and fast-acting DC breakers at strategic locations

open access: yesThe Journal of Engineering, 2019
DC fault protection arrangements for a large multi-terminal HVDC (MTDC) network are proposed where fast-acting DC circuit breakers are only used at strategic locations with the large DC network to be operated interconnected but partitioned into islanded ...
Md Habibur Rahman   +4 more
doaj   +1 more source

Oil Circuit Breakers [PDF]

open access: yesTransactions of the American Institute of Electrical Engineers, 1915
The purpose of the paper is to present a brief explanatory discussion of some of the arc phenomena in oil circuit breakers and to describe the present tendencies in oil breaker construction and practise. A proposed method for rating breakers and specifying is included.
openaire   +1 more source

DC fault protection strategy considering DC network partition [PDF]

open access: yes, 2016
This paper investigates DC network partition and alternative DC fault protection strategy for Multi-terminal HVDC (MTDC) system. Fast acting DC Circuit Breakers (DCCBs) or fault blocking DC-DC converters can be configured at strategic locations to allow ...
Rahman, Md Habibur   +2 more
core   +1 more source

Home - About - Disclaimer - Privacy