Results 51 to 60 of about 39,446 (240)
Applications of a Novel Wireless System for Real‐Time Atmospheric Corrosion Monitoring
Developed monitoring system is a powerful tool for real‐time atmospheric corrosion monitoring. Humidity plays a critical role in the corrosion process. Limiting environmental parameters inducing maximum corrosion vary depending on the pollutants present. A monitoring system can be used in a wide range of scientific and practical applications.
Kateryna Popova +3 more
wiley +1 more source
Objective Arc extinction technology for DC (direct current) is one of the design challenges in urban rail transit traction power supply systems. Therefore, it is necessary to analyze the principles of DC opening and arc extinction for main DC fast ...
MENG Junfeng +3 more
doaj +1 more source
Short- circuit tests of circuit breakers [PDF]
This paper deals with short-circuit tests of low voltage electrical devices. In the first part of this paper, there are described basic types of short- circuit tests and their principles.
Chorovský, P.
core
Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management [PDF]
Peer ...
Jovcic, Dragan +3 more
core +1 more source
Key Findings: An assimilation methodology is established for the Tomorrow.io microwave sounder (TMS) flying on CubeSats in sun‐synchronous and inclined orbits, and in all cloud scenes. The TMS has a significant impact on weather forecast lead times up to 3 days in the Tropics in a research‐quality numerical weather prediction setting, and yields water ...
Jonathan J. Guerrette +3 more
wiley +1 more source
A capacitive high voltage DC circuit breaker incorporating a current limiting function
DC circuit breakers, as one of the vital devices for fault clearance in DC power systems, significantly influence the secure and stable operation of the system.
TU Lizhong +4 more
doaj +1 more source
: The article presents an algorithm for estimating reliability parameters - probability of failure-free operation time and failure rate of low-voltage switching devices based on statistical data on failures of circuit breakers installed in control and ...
E. I. Gracheva +3 more
doaj +1 more source
Spring operation mechanism is widely used in high voltage circuit breakers, and its reliability is related to the ability of the circuit breaker breaking fault current. During the life cycle of spring operating mechanism, stress relaxation, metal fatigue,
Yakui Liu +5 more
doaj +1 more source
Influence of UHV GIL access on transient recovery voltage of circuit breaker
The access of ultra high voltage (UHV) gas-insulated transmission line (GIL) affects both the transient recovery voltage (TRV) amplitude and the rate of rise of TRV (RRRV) of circuit breakers,which may endanger the breaking capacity of circuit breakers ...
SUN Yi +5 more
doaj +1 more source
Thermally responsive mechanical actuator [PDF]
Device built for use in heat control, heat measurement, and mechanical actuation by heat include thermometers, thermostats, safety switches, circuit breakers, and mechanical actuators.
Madey, J. M.
core +1 more source