Results 91 to 100 of about 2,164 (196)

Intracardiac Echocardiography‐Guided Radiofrequency Ablation in Atrial Fibrillation

open access: yes
Echocardiography, Volume 42, Issue 6, June 2025.
Jiaqi Wang, Lang Wang, John T. W. Yeow
wiley   +1 more source

Analysis and Design of a Multiplex, Delay‐and‐Sum (MDAS) Beamformer Architecture to Implement a Fixed‐Focus Receive Beamformer for Portable Ultrasound Imaging Systems

open access: yesJournal of Electrical and Computer Engineering, Volume 2024, Issue 1, 2024.
A multiplex, delay‐and‐sum (MDAS) architecture is proposed to implement a fixed‐focus receive beamformer such as the first stage of the synthetic aperture sequential beamforming (P‐SASB) and synthetic transmit beams combined with the P‐SASB (STB‐P‐SASB) beamforming methods.
Sadegh Dashti, Omid Shoaei, Andrea Tani
wiley   +1 more source

Çökme modu CMUT alıcısının rezonans altı duyarlılık hassasiyet en iyilieştirilmesi

open access: yes, 2018
Cataloged from PDF version of article.Includes bibliographical references (leaves 49-52).Capacitive Micromachined Ultrasonic Transducer (CMUT) has a flexural conductive plate suspended over a fixed substrate with metal electrode deposited over it. This
Khan, Mansoor
core  

BCB polymer based row-column addressed CMUT

open access: yes, 2017
This paper presents an inexpensive, low temperature and rapid fabrication method for capacitive micromachined ultrasonic transducers (CMUT). The fabrication utilizes the bonding and dielectric properties of the photosensitive polymer Benzocyclobutene ...
Engholm, Mathias   +11 more
core   +1 more source

Simulating CMUT Arrays Using Time Domain FEA [PDF]

open access: yes, 2017
PZFlex is a commercial FEA software that has been optimized for the ultrasound industry and is commonly used to design piezoelectric ultrasound transducers. However, PZFlex is not commonly used within the CMUT research field.
Jorgen Arendt Jensen   +13 more
core   +1 more source

Lumped-Parameter Equivalent Circuit Modeling of CMUT Array Elements

open access: yes, 2021
International audienceDesign and modeling are key steps in the value chain of Capacitive Micromachined Ultrasonic Transducer (CMUT) arrays. Although CMUT array element models are very powerful, most of them are still limited in their use as tools for ...
Boulmé, Audren   +2 more
core   +1 more source

Design and implementation of CMUT multi-channel ultrasonic transceiver board based on PXIe

open access: yesDianzi Jishu Yingyong
To enable multi-channel pulse transmission, data acquisition, storage, transmission, and analysis based on a capacitive micromachined ultrasonic transducer (CMUT) array, a 32-channel ultrasound transceiver board was designed based on the PXIe bus.
Wu Shuaiqi   +5 more
doaj   +1 more source

A Capacitive Micromachined Ultrasonic Transducer-Based Resonant Sensor Array for Portable Volatile Organic Compound Detection with Wireless Systems

open access: yesSensors, 2019
The development of portable volatile organic compound (VOC) sensors is essential for home healthcare and workplace safety because VOCs are environmental pollutants that may critically affect human health.
Inug Yoon   +5 more
doaj   +1 more source

Multiple Element Electrode Cmut Devices And Fabrication Methods

open access: yes, 2010
Multiple electrode element capacitive micromachined ultrasonic transducer ("cMUT") devices and fabrication methods are provided. Some embodiments can include a forward or side looking catheter device having a plurality of cMUT arrays for transmitting and

core  

Advances in Capacitive Micromachined Ultrasonic Transducers

open access: yesMicromachines, 2019
Capacitive micromachined ultrasonic transducer (CMUT) technology has enjoyed rapid development in the last decade. Advancements both in fabrication and integration, coupled with improved modelling, has enabled CMUTs to make their way into mainstream ...
Kevin Brenner   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy