Results 101 to 110 of about 749,316 (193)
Custom integrated circuit design for ultrasonic therapeutic CMUT array
This paper presents the design of a highly flexible and programmable transmit beam-former ASIC using a high voltage (HV) 0.35 μm CMOS technology to be flip-chip bonded to a 4 × 4 CMUT array for ultrasound therapeutic applications. However, proposed IC can be used as a transmitter circuitry in color Doppler 3D imaging applications. In our proposed chip,
Maadi, Mohammad, Bayram, Baris
openaire +3 more sources
Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays
Integration of front-end electronics with 2D capacitive micromachined ultrasonic transducer (CMUT) arrays has been a challenging issue due to the small element size and large channel count.
Karaman, Mustafa +2 more
core +1 more source
Capacitive Micromachined Ultrasonic Transducers (CMUTs) feature broadband operation as well as high sensitivity, showing promise for applications such as pressure sensing, ultrasonic imaging, and wireless power transfer.
Yilihamu Abudujiasuer +4 more
doaj +1 more source
Capacitive Micromachined Ultrasonic Transducers (CMUTs) provide a path to mass-produced cost-efficient transducers for clinical imaging and wearables. However, their inherent nonlinearities, especially at high excitation voltages, can degrade performance
Tonnis Trittler +9 more
doaj +1 more source
Acoustic emission (AE) monitoring in metal additive manufacturing (AM) requires compact sensors capable of high-frequency operation, broad bandwidth, and high sensitivity.
Sulaiman Mohaidat +3 more
doaj +1 more source
Minimally invasive catheter-based electrophysiological (EP) interventions are becoming a standard procedure in diagnosis and treatment of cardiac arrhythmias.
Khuri-Yakub, B. T. +6 more
core +1 more source
We designed and fabricated a 64 element 1-D linear dual electrode Capacitive Micromachined Ultrasonic Transducer (CMUT) array operating at 9.5 MHz for Intracardiac Echocardiography (ICE).
Karaman, Mustafa +3 more
core +1 more source
In a recent study using 3-D fullwave simulations, it was shown for a nonhuman primate model that a helmet-shaped 3D array of 128 transducer elements can be assembled for neurostimulation in an optimized configuration with the accommodation of an imaging ...
Tamzid Ibn Minhaj +5 more
doaj +1 more source
Multiphysical model of CMUT array based on modal decomposition and the Rayleigh integral
There is a high number of modeling techniques for calculation of characteristics of capacitive micromachined ultrasound transducers. Very few of them are capable of calculation of the acoustic field, especially when the number of cells in the array is ...
A.E. Biriukov, A.M. Korsunsky
doaj +1 more source
CMUT sensors based on circular membranes array for SHM applications
International audienceA MEMS sensor dedicated to SHM applications is presented. The MEMS is made of a Capacitive Micromachined Ultrasonic Transducer (CMUT) chip composed of circular membranes array.
Le Moal, Patrice +6 more
core

