Results 111 to 120 of about 749,316 (193)
Integrated ultrasonic imaging systems based on CMUT arrays: Recent progress
This paper describes the development of an ultrasonic imaging system based on a two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array.
Yeh, David T. +7 more
core +1 more source
Small-Signal Equivalent Circuit Model of Long Rectangular CMUT Membranes
Capacitive micromachined ultrasound transducers (CMUTs) are typically designed with many small membranes per linear array element. However, these membranes can operate out of phase or collapse at different voltages, leading to suboptimal transmit ...
Eric B. Dew +5 more
doaj +1 more source
Elmas Membranlı 1-B CMUT Dizilerinin Tasarımı ve Geliştirilmesi
This thesis presents a new microfabrication method of 1-D capacitive micromachined ultrasonic transducer (CMUT) array featuring diamond membrane.
Karacaer, Berkay
core
Tiles CMUT dies with pitch uniformity
A large aperture CMUT transducer array is formed of a plurality of adjacently located tiles of CMUT cells. The adjacent edges of the tiles are formed by an anisotropic etch process, preferably a deep reactive ion etching process which is capable of ...
Henneken, V.A. (author) +4 more
core
Gravimetric resonant-inspired biosensors have attracted increasing attention in industrial and point-of-care applications, enabling label-free detection of biomarkers such as DNA and antibodies. Capacitive micromachined ultrasonic transducers (CMUTs) are
Zhikang Li +9 more
doaj +1 more source
Air-coupled CMUT arrays based on MUMPS
Funding from DPI2004-06756-C03-01 and 03 – CICYT projects is acknowledged.
Octavio Manzanares, Alberto +4 more
openaire +1 more source
Ex Vivo HIFU Experiments Using a $32 \times 32$ -Element CMUT Array. [PDF]
Yoon HS +9 more
europepmc +1 more source
Fabrication and Testing of a 64-Element CMUT Ring Array for Underwater Ultrasound Imaging
Capacitive micromachined ultrasonic transducers (CMUTs) have demonstrated great potential in ultrasonic imaging due to their wide bandwidth, high electromechanical coupling coefficient, flexible design, and ease of integration.
Zhang, Guojun +22 more
core +1 more source
Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array. [PDF]
Novell A, Arena CB, Kasoji S, Dayton PA.
europepmc +1 more source
Annular CMUT Arrays for Side Looking Intravascular Ultrasound Imaging
Although side looking intravascular ultrasound (SL-IVUS) imaging systems using single element piezoelectric transducers set the resolution standard in the assessment of the extent of coronary artery disease, improvements in transducer performance are needed to perform harmonic imaging and high resolution imaging of vulnerable plaque.
Zahorian, Jaime +8 more
openaire +2 more sources

