Results 201 to 210 of about 3,785 (263)
Some of the next articles are maybe not open access.

Electronic charge exchange at insulator-insulator interface in insulating composites

Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM), 2002
The charge exchange at the insulator-insulator interface in insulating composites is affected by the direction of the carrier transport and carrier species. In this paper the charge exchange process at the PS-PMMA interface was discussed on the basis of asymmetric photoconduction and contact charging.
A. Kawamoto   +4 more
openaire   +1 more source

The breakdown of composite insulation

Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1972, 1972
It is frequently assumed that composite insulation, consisting for example, of a column of air in series with a solid dielectric, breaks down because a discharge in the weaker gaseous section acts like a thin conducting extension of the electrode.
R. Cooper, D. W. Auckland
openaire   +1 more source

Installing insulation jacket to improve outdoor insulation performance of composite insulator

IEEE Transactions on Dielectrics and Electrical Insulation, 2011
In the paper, a new approach is proposed to improve the outdoor insulation properties of transmission lines. It is achieved by installing the insulation jackets and additional grading rings onto transmission line conductors. The impact of insulation jacket parameters on the electrical field distribution along a 220 kV composite insulator was simulated ...
Hongwei Mei   +5 more
openaire   +1 more source

Composite Post Insulators

2013
In contrast to composite long rods, composite post insulators are subjected mainly to loads which act perpendicular to the longitudinal axis of the insulator and thus produce bending stresses over the cross-section of the insulator. As a result of this bending load, composite post insulators use FRP rods of substantially greater diameter compared to ...
Konstantin Papailiou, Frank Schmuck
openaire   +1 more source

Swedish research on the application of composite insulators in outdoor insulation

IEEE Electrical Insulation Magazine, 1995
Swedish research on the use of composite insulators in outdoor insulation focuses on investigations in natural and artificial conditions, new diagnostic test methods, and the effects of ageing and hydrophobicity variations. Basic flashover phenomena on hydrophobic surfaces also are being studied. >
S. Gubanski, R. Hartings
openaire   +1 more source

Hydrophobicity and insulated resistance of composite insulators with biological contamination

2016 IEEE International Conference on High Voltage Engineering and Application (ICHVE), 2016
Biological growth has been observed on insulators installed all over the world. However its impact on the electrical performance is not well known. This paper described the investigations on the performance of post insulators with biological growth at a converter station. Both the ceramic and composite insulators were investigated.
Gulin Xia   +4 more
openaire   +1 more source

Characteristics of Composite Insulation: Liquid-Impregnated Insulation

IEEE Transactions on Electrical Insulation, 1986
A description is given of composite insulation, i. e. swelling of polymers by oil, oil streaming electrification of solid dielectrics , and V-t characteristics of LN2-impregnated insulation due to partial discharge. Swelling can be accelerated by ultrasonic wave irradiation. This reduces the saturation time.
openaire   +1 more source

Insulating gas composition

2023
CHEN LUJIA   +3 more
openaire   +2 more sources

AC failure voltage of iced and contaminated composite insulators in different natural environments

International Journal of Electrical Power and Energy Systems, 2020
Xinhan Qiao, Xingliang Jiang
exaly  