Results 31 to 40 of about 105,810 (312)

Mechanical Response of CNT/2024Al Composite to Compression and Tension at Different Strain Rates

open access: yesMetals, 2023
Compressive and tensile properties of a carbon nanotube (CNT) reinforced 2024Al composite are investigated under quasi-static and dynamic compression as well as quasi-static tension, along three different directions (extrusion, normal and transverse ...
Jiajie Xiang   +3 more
doaj   +1 more source

A numerical study on impact and compression after impact behaviour of variable angle tow laminates [PDF]

open access: yes, 2013
Recent developments of variable angled tow (VAT) technology have indicated that variable stiffness composite laminates offer a strong potential for structural tailoring.
Dang, Thi D., Hallett, Stephen R.
core   +1 more source

How do compression and flexion-compression injuries destabilize the spine? A novel in vitro protocol for analyzing three-dimensional biomechanical instability

open access: yesFrontiers in Bioengineering and Biotechnology
IntroductionUnstable traumatic spinal injuries require surgical stabilization. However, biomechanical instability of specific spinal injuries has been little investigated, although restoring stability represents a primary goal of surgical treatment. This
Ann-Kathrin Greiner-Perth   +2 more
doaj   +1 more source

Experimental study on the fracture behavior of AZ91D magnesium alloy under complex loading

open access: yesResults in Physics, 2020
In this study, quasi-static compression, tensile, shear, and combined compression-shear tests are conducted on cast AZ91D magnesium (Mg) alloy to study its fracture behavior.
Zai Wang, Ji Qiu, Xuefeng Shu, Tao Jin
doaj   +1 more source

Major spinal surgery procedure on a high cardiovascular risk patient with symptomatic neural compression due to 1: Osteoporotic T12 compression fracture along with 2—L5/S1 spondylolisthesis

open access: yesJournal of Spinal Surgery, 2014
Introduction: Osteoporotic vertebral fracture most common located at thoracolumbar junction, whereas most spondylolisthesis at L4-5 is six to 10 times more frequent involved than adjacent level.
Sumeet G Pawar   +2 more
doaj   +1 more source

Ofatumumab in Myelin Oligodendrocyte Glycoprotein Antibody–Associated Disease: A Comparison With Rituximab

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective To evaluate the efficacy and safety of ofatumumab in patients with myelin oligodendrocyte glycoprotein antibody–associated disease (MOGAD), and compare it with rituximab. Methods We conducted a single–center, observational study including 22 MOGAD patients treated with ofatumumab and 21 treated with rituximab.
Yuxin Fan   +5 more
wiley   +1 more source

Prognostic Factors of Percutaneous Vertebroplasty for Vertebral Compression Fracture and Risk Factors of New Symptomatic Compression Fracture

open access: yesFormosan Journal of Musculoskeletal Disorders, 2023
Background: Vertebral compression fractures (VCFs) are a common complication of osteoporosis and can lead to severe pain, decreased mobility, and reduced quality of life. Percutaneous vertebroplasty (PVP) is an effective minimally invasive procedure used
Wen-Chien Wang   +6 more
doaj   +1 more source

Early Clinical, Imaging, and Pathological Characteristics of SRPK3/TTN‐Digenic Myopathy

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective SRPK3/TTN‐digenic myopathy was recently established as a skeletal muscle myopathy caused by digenic inheritance. This study characterizes the early clinical presentation of SRPK3/TTN‐digenic myopathy in one previously reported and seven newly identified pediatric patients.
Rotem Orbach   +23 more
wiley   +1 more source

Mechanical performance and fracture behavior of Fe₄₁Co₇Cr₁₅Mo₁₄Y₂C₁₅B₆ bulk metallic glass

open access: yes, 2007
The mechanical properties of a new Fe₄₁Co₇Cr₁₅Mo₁₄Y₂C₁₅B₆ bulk glassy alloy were studied by impact bending, compression, and hardness tests carried out at room temperature.
Shen, Jun   +3 more
core   +1 more source

Chest X-Ray Assessment is Incomplete without the Lateral View [Letter]

open access: yesAdvances in Medical Education and Practice, 2021
Bruce Rothschild IU Health, Muncie, IN 47303, USACorrespondence: Bruce RothschildIU Health, Muncie, IN 47303, USATel +1-7856151523Email Spondylair@gmail.comThe article by Sait and Tombs1 represents an important contribution to the preparation of ...
Rothschild B
doaj  

Home - About - Disclaimer - Privacy