Results 231 to 240 of about 96,508 (303)
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner +14 more
wiley +1 more source
Providing a computationally derived, mechanically optimised target correction during preoperative planning can improve joint contact mechanics of hip dysplasia treated with periacetabular osteotomy. [PDF]
Aitken HD +6 more
europepmc +1 more source
A 3D anisotropic hydrogel derived from heart extracellular matrix guides cytoskeletal alignment and nuclear remodeling in reprogrammed cardiomyocyte‐like cells. This study reveals how matrix alignment modulates nuclear envelope dynamics and chromatin state, triggering transcriptional and functional maturation.
Seung Ju Seo +7 more
wiley +1 more source
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
A swelling‐programmed micropatterned hydrogel guides adherent cells through a controlled transition from cell–matrix anchoring to cadherin‐mediated cell–cell compaction, enabling rapid assembly of high‐viability spheroids with defined size and morphology.
Han Gyeol Nam +8 more
wiley +1 more source
Incorporating patient-specific hip orientation from weightbearing computed tomography affects discrete element analysis-computed regional joint contact mechanics in individuals treated with periacetabular osteotomy for hip dysplasia. [PDF]
Rivas DJ +5 more
europepmc +1 more source
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source

