Results 111 to 120 of about 2,953,458 (303)

Fretting wear of lubricated DLC coating systems

open access: yesFrontiers in Mechanical Engineering
Diamond-like Carbon (DLC) coatings are well known for their use in protection against fretting wear due to their low friction and wear properties. DLCs are metastable, allowing them to graphitise under applied load to create a graphitic transfer layer ...
Samuel J. McMaster   +4 more
doaj   +1 more source

Clinical Practice Guideline for Evaluation and Management of Peripheral Nervous System Manifestations in Sjögren's Disease

open access: yesArthritis Care &Research, EarlyView.
Objective Sjögren's disease is an autoimmune disorder that can impact multiple organ systems, including the peripheral nervous system (PNS). PNS manifestations, which can exist concurrently, include mononeuropathies, polyneuropathies, and autonomic nervous system neuropathies.
Anahita Deboo   +88 more
wiley   +1 more source

Temporal Trends and Short‐ and Long‐Term Mortality of People With Acute Myocardial Infarction and Rheumatoid Arthritis: A Nationwide Cohort Study

open access: yesArthritis Care &Research, EarlyView.
Objective We investigated whether a diagnosis of rheumatoid arthritis (RA) affects the quality of inpatient acute myocardial infarction (AMI) care and long‐term mortality post‐AMI. Methods We analyzed data from 784,091 adults, 6,047 with a diagnosis of RA, from England and Wales hospitalized with AMI between 2005 and 2019 from the Myocardial Ischaemia ...
Megan Butler   +8 more
wiley   +1 more source

Finite-element analysis of contact between elastic self-affine surfaces

open access: yes, 2004
Finite element methods are used to study non-adhesive, frictionless contact between elastic solids with self-affine surfaces. We find that the total contact area rises linearly with load at small loads.
B. B. Mandelbrot   +9 more
core   +1 more source

Patellofemoral contact pressures.

open access: yesActa of bioengineering and biomechanics, 2009
A test rig for studying the biomechanical behaviour of post-mortem human knees is built. For loading the quadriceps tendon a special clamping device is constructed, so the forces up to 3000 N could easily be transferred to the tendon. Several post-mortem human knees used in this study are tested to collect data about the general biomechanics of knee ...
Jan, Quintelier   +4 more
openaire   +1 more source

Does Long‐Term Lower Extremity Strength Training in Adults With Knee Osteoarthritis and Varus Alignment Reduce Knee Joint Loading During Gait?

open access: yesArthritis Care &Research, EarlyView.
Objective We examined whether 18 months of strength training in individuals with knee varus alignment and medial tibiofemoral osteoarthritis (OA) reduced knee joint loads during walking compared to an attention control group. Methods This study was a secondary analysis of a randomized clinical trial that compared the effects of strength training to a ...
Stephen P. Messier   +12 more
wiley   +1 more source

Pain and Patient‐Reported Physical Function Did Not Differ Among Body Composition Profiles in Patients With Hip Osteoarthritis

open access: yesArthritis Care &Research, EarlyView.
Objective To explore whether higher body fat and lower lean mass are associated with greater pain and worse patient‐reported physical function in individuals with hip osteoarthritis (OA). A secondary aim was to examine whether pain and patient‐reported physical function differ according to four body composition profiles: high body fat, low lean mass ...
Alexandra Ryan   +10 more
wiley   +1 more source

Numerical Simulation Analysis of Influences of Microgroove Texture on Friction Performance of Expansion Cone

open access: yesShiyou jixie, 2023
The current evaluation of expandable tubulars focuses on the expansion quality and neglects the friction performance of the expansion cone.Given this,the elastoplastic theoretical derivation is performed to calculate the counteractive surface pressure ...
Wang Xin   +5 more
doaj  

Effect of surface asperity on elastohydrodynamic lubrication [PDF]

open access: yes
The important aspects of elastohydrodynamic lubrication, with a single, one-dimensional asperity, have been found by solving numerically the coupled transient Reynolds equation and the elasticity equation.
Cheng, H. S., Lee, K.
core   +1 more source

Arterial pulse wave pressure transducer [PDF]

open access: yes, 1974
An arterial pulse wave pressure transducer is introduced. The transducer is comprised of a fluid filled cavity having a flexible membrane disposed over the cavity and adapted to be placed on the skin over an artery.
Chen, W., Gorelick, D., Kim, C.
core   +1 more source

Home - About - Disclaimer - Privacy