Cooling Loss Characteristics of Working Fluid Pump for Pump-driven Two-phase Circulation Loop

open access: yesZhileng xuebao, 2020
A pump-driven two-phase circulation loop system was built for data center cooling in order to make full use of the ambient energy. In this study, the cooling loss characteristic of working fluid pump was investigated by changing the system temperature ...
Li Cuicui   +3 more
doaj  

The Effect of Increasing Sub-Cooling on Air-Cooled A/C System's Capacity

open access: yesJournal of Engineering and Sustainable Development, 2009
The present research covers the effect of adding an extra water-cooled condenser in series with the main vapor compression refrigeration system as a heat sink source for system sub-cooling. An experimental laboratory study has been done on a split unit air conditioner with a (24000 Btu/hr) nominal capacity, taking into consideration the effect of ...
Ghanim K. Abdul Sada   +2 more
openaire   +1 more source

Experimental and Numerical Investigation of a Refrigerator Unit for a Refrigerated Vehicle

open access: yesZhileng xuebao
To examine the influence of different parameters of a 10 kW refrigeration unit on the performance of a refrigerated vehicle, the capacity, coefficient of performance (COP), and pressure performance of the circulation system of a refrigeration unit were ...
Wang Zhenhuan   +2 more
doaj  

Analisis Beban Pendinginan di Ruang Kelas F212 Institut Teknologi Sumatera

open access: yesQuantum Teknika
Cooling load analysis in the classroom is carried out to support a comfortable learning process. Determining the cooling load is the foundation for planning an air conditioning system for a room.
Daniel Manurung   +6 more
doaj   +1 more source

Adsorption Refrigeration Characteristic of Attapulgite Based Calcium Chloride Composite Adsorbents

open access: yesZhileng xuebao, 2012
The composite absorbent is mainly consisted of attapulgite and CaCl2 as the resources, which were prepared by the dissolution-mixed method, and the content of attapulgite in composite absorbent is 10%.
Wan Yi   +6 more
doaj  

Temperate wetlands lose climate-cooling capacity under warming. [PDF]

open access: yesNat Commun
Ma S   +4 more
europepmc   +1 more source

On the Cooling and Concentrating Capacities of the Natural Draft Type Cooling Tower

open access: yesBulletin of the Society of Sea Water Science, Japan, 1968
SAKAI, Yoshiyuki   +3 more
openaire   +1 more source