Results 21 to 30 of about 891,437 (305)

Very long distance connection of gigawatt size offshore wind farms: extra high-voltage ac versus high-voltage dc cost comparison [PDF]

open access: yes, 2016
This study presents a cost comparison between commercially available high-voltage DC (HVDC) and extra high-voltage AC shore connection (±320 kV voltage source converter and 420 kV-50 Hz single-core and three-core cables), for a 1 GW offshore wind farm ...
LAURIA, Stefano   +3 more
core   +1 more source

Power Losses Models for Magnetic Cores: A Review

open access: yesMicromachines, 2022
In power electronics, magnetic components are fundamental, and, unfortunately, represent one of the greatest challenges for designers because they are some of the components that lead the opposition to miniaturization and the main source of losses (both ...
Daniela Rodriguez-Sotelo   +5 more
doaj   +1 more source

A New Application of Transient Recorder to Magnetic Measurements (Part I: Core Loss Measurement at Very Low Frequencies) [PDF]

open access: yes, 1976
A new method have been developed based upon analogue-to-digital conversion techniques and memories. The method involves the scaling of operating frequency from "real" to "optimum" for the power loss measurement.
Ishihara, Yoshiyuki   +3 more
core   +1 more source

Postfault Operation of Five-Phase Induction Machine With Minimum Total Losses Under Single Open-Phase Fault

open access: yesIEEE Access, 2020
Five-phase induction machines (FPIM) have attracted notable interest in safety critical applications as well as wind energy generation systems. This is largely due to their additional degrees of freedom that retain the machine starting/running steadily ...
Abdullah Shawier   +4 more
doaj   +1 more source

PCF Based Sensor with High Sensitivity, High Birefringence and Low Confinement Losses for Liquid Analyte Sensing Applications [PDF]

open access: yes, 2015
In this paper, we report a design of high sensitivity Photonic Crystal Fiber (PCF) sensor with high birefringence and low confinement losses for liquid analyte sensing applications.
Ademgil, Huseyin, Haxha, Shyqyri
core   +3 more sources

Minimum Loss Operation and Optimal Design of High-Frequency Inductors for Defined Core and Litz Wire

open access: yesIEEE Open Journal of Power Electronics, 2020
This paper studies the loss-optimal design of a power inductor employed in a 2 kW, 400 V input DC-DC converter. The design of an inductor is subject to a large number of design parameters and the implications of the different design parameters on the ...
Panteleimon Papamanolis   +3 more
doaj   +1 more source

Determination of Core Losses Using an Inverse Modeling Technique

open access: yesIEEE Access, 2022
This paper presents an inverse thermal modeling technique to determine the core losses from the temperature rise inside the transformer core. For this purpose, initially, a customized printed circuit board (PCB) with thermal sensors is used to measure ...
Osaruyi Osemwinyen   +5 more
doaj   +1 more source

M82 - A radio continuum and polarisation study I. Data reduction and cosmic ray propagation [PDF]

open access: yes, 2013
The potential role of magnetic fields and cosmic ray propagation for feedback processes in the early Universe can be probed by studies of local starburst counterparts with an equivalent star-formation rate.
Adebahr, B.   +5 more
core   +2 more sources

Determination of Core Losses in Open-Core Power Voltage Transformers

open access: yesIEEE Access, 2018
Power voltage transformers (PVTs) are becoming increasingly present in different substation solutions on a world scale. Such units that are based on the open-core concept introduce several advantages in terms of transformer performance and reliability ...
Igor Ziger, Bojan Trkulja, Zeljko Stih
doaj   +1 more source

An Ultra-Low Bending Loss Negative Curvature Hollow Core Fiber With a Polygon Jacketing Layer

open access: yesIEEE Photonics Journal, 2023
We design and simulate a new type of hollow-core antiresonant fiber with the polygon jacketing layer. Through numerical calculations, the confinement loss is approximately 0.003 dB/km at 1.45 μm and the bandwidth is ∼ 410 nm @
Yun-Hao Xu   +6 more
doaj   +1 more source