Results 251 to 260 of about 61,940,678 (296)
Some of the next articles are maybe not open access.

A curing cycle for detector-quality CR-39

Nuclear Tracks, 1981
ABSTRACT Commercially available CR-39 has been found to etch non-uniformly as a function of depth through the thickness of a sheet. This apparently occurs because the sheet overheats internally during polymerization. Results are presented on a curing cycle designed to maintain a low rate of polymerization throughout the curing process.
openaire   +1 more source

136Xe and 197Au ion track registration response in CR-39 and CR-39 (DOP) detectors

Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1994
Abstract Samples of CR-39 and CR-39 (DOP) plastic track detectors were exposed to 136Xe ions (11.56 MeV n ) and 197Au ions (13.92 MeV n ) at an angle of 45° from UNILAC, GSI, Darmstadt, Germany, to study the track registration parameters, viz. variation of track length (L) with etching temperature (55°, 65°, 70° and 80°C) using 6N NaOH as
Ashavani Kumar, Rajendra Prasad
openaire   +1 more source

Dose rate dependence on the response of CR-39 SSNT-Detector

The International Journal of Applied Radiation and Isotopes, 1985
The dose rate dependence on the response of CR-39 SSNT-Detector was examined. The dose rate region studied was 10(2)-10(6) rad/min for doses 0 up to 1 Mrad. For relatively low and high dose rates a drop in the response of the detector was observed. The behavior changes for low doses and above 1 Mrad.
M, Zamani, S, Charalambous
openaire   +2 more sources

STATUS OF DEVELOPMENT IN THE FIELD OF CR-39 TRACK DETECTORS

Nuclear Tracks, 1981
ABSTRACT The present situation concerning the manufacture and etching characteristics of the CR-39 nuclear track detector is surveyed. Especial attention is paid to the trends in research and to the outstanding questions related to the subject. The requirements and procedures in connection with the manufacture of high-quality, thick and thin detector
openaire   +1 more source

Proton Detection with CR-39 Track Detector

Radiation Protection Dosimetry, 1996
Hungarian produced CR-39 detectors irradiated with protons of energy 3-18 MeV and with 14.7 MeV neutrons through a thick PE radiator were etched at 22°C and 70°C in NaOH solution. The increase in diameter of tracks as a function of proton energy was measured.
openaire   +1 more source

AN IMPROVED CR-39 TRACK DETECTOR FOR COSMIC RAY APPLICATIONS

Nuclear Tracks, 1981
ABSTRACT Batches of CR-39 polymer have been produced using a temperature-time polymerisation cycle designed to minimise temperature gradients during curing. Track detector evaluation tests of these batches were carried out using Argon and Iron beams at the LBL Bevalac. The results indicate a significant improvement in the uniformity of track response
A. Thompson   +6 more
openaire   +1 more source

Plate-out effects in CR-39 detectors

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1985
Abstract A study of “plate-out” effects in CR-39 detectors in indoor environment was made. The detectors were exposed to airborne particles, settled down onto a surface placed at various distances from the detectors. The effect was estimated to be about 30% in indoor air.
openaire   +1 more source

Study on response of CR-39 detector to light ions

Radiation Measurements, 1999
Abstract The response of CR-39 detector has been obtained precisely for protons, deuterons, tritons, alpha-particles and lithiumions with energies of a few MeV/nucleon. The track etch rates were determined from the growth curves of pit radius and summarized as the response functions.
T. Yamauchi, T. Taniguchi, K. Oda
openaire   +1 more source

Computer simulation of the processes in a CR-39 neutron detector

Radiation Measurements, 2003
The application of CR-39 as a fast neutron dosimeter, based on counting elastic recoil nuclei tracks of H, C and O nuclei in a geometrically matched pair of detectors, was studied. A computer simulation of the processes during the exposure of a detector pair to neutrons is presented.
I. Lengar, J. Skvarč, R. Ilić
openaire   +1 more source

Sunlight effect on sensitivity and performance of the CR-39 detector

International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 1991
Abstract The effect of sunlight on CR-39 detector has been investigated. It has been found that the response of the detector to full energy α particles from a 252Cf source and neutrons from an Am-Be source drops by ∼ 60% and 87%, respectively. The detectors exposed to sunlight for more than 60 days were found to be completely fogged and there ...
F. Ansari   +4 more
openaire   +1 more source

Home - About - Disclaimer - Privacy