Results 261 to 270 of about 61,940,678 (296)
Some of the next articles are maybe not open access.

The development of neutron dosimeter using CR-39 detector

Radiation Effects and Defects in Solids, 1994
Abstract The local demands for an improved neutron dosimeter have been grown in recent years. This work outlines a design for a dosimeter to measure incident neutron doses with any energy (thermal, intermediate and fast). Moreover this study presents the effect of radiators and converters on the sensitivity of chemically etched CR-39 detectors, as well
A. M. El-khatib   +3 more
openaire   +1 more source

An extended study of the etching characteristics of CR-39 detectors

Radiation Measurements, 2009
An analysis concerning the bulk etch rate of different type of CR-39 subjected to a chemical etching in 5.4 N KOH solution at 80 °C is carried out in the present work. The response of PADC samples has been evaluated adopting the fission fragment track diameter method.
F. Leonardi   +6 more
openaire   +1 more source

Prospecting oil and gas deposits with CR-39 detectors

Nuclear Tracks and Radiation Measurements, 1993
Abstract The radon (222Rn) concentrations in soil gases have been measured with the CR—39 detectors and gamma—ray radiation of the soil samples were collected with a high purity germanium detector in both Saihantala Hollow, Inner Mongolia and Weibei Hollow, Shandong. A few oil and gas deposits have been traped with their anomalies.
null Lu Zuhui   +5 more
openaire   +1 more source

Characterization of CR-39 detectors for monitoring indoor radon 222

Applied Radiation and Isotopes
Radon gas (Rn-222) is a carcinogenic agent classified by the WHO as Group 1 and is the leading cause of lung cancer in non-smokers. Due to its natural origin in the Earth's crust, this gas is primarily transported by exhalation through cracks, with concentrations that vary depending on soil morphology and climatic seasons.
S A, Martinez-Ovalle   +3 more
openaire   +2 more sources

Post-irradiation annealing in plastic detector CR-39

International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 1988
Abstract Thermal stability of latent damage trails due to 18 MeV/n 93 Nb ions in CR-39 detector was studied. The samples were annealed in the temperature range 100°C – 250°C for time intervals of 10 min., 20 min. and 40 min. and subsequently etched in 6N NaOH solution at 70° + 1°C.
R.K. Bhatia, H.S. Virk
openaire   +1 more source

Critical angles of etching of CR-39 track detectors

The International Journal of Applied Radiation and Isotopes, 1984
Abstract The critical angles of etching of CR-39, the latest member of the SSNTD family have been determined for a number of light and heavy charged particles, having a wide spectrum of energies. It has been observed that the critical angles increase with the decreasing value of the parameter, Zeff2/β2 of the charged particles.
Hameed A. Khan   +3 more
openaire   +1 more source

Response of electrochemically etched CR-39 detectors to protons

Radiation Measurements, 1999
The neutron response of electrochemically etched (ECE) CR-39 detectors is determined by the energy and angular dependence of the response to neutron-induced charged particles. This response has been measured for the example of protons with various initial energies and angles of incidence.
B. Dörschel, D. Hermsdorf, K. Kadner
openaire   +1 more source

CR-39 nuclear track detector: An experimental guide

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
Abstract The influence of preservation period of CR-39 detectors, in refrigerator and in the laboratory atmosphere, on bulk etch rate is studied. The effect of etching solution usage time on the bulk etch rate is also investigated. Analyses and quantitative results in the said cases are presented.
openaire   +1 more source

Sensitivity study of CR-39 plastic track detectors

International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 1992
Abstract With the goal of increasing the sensitivity of CR-39 plastic track-recording detectors, samples of plastics that contain antioxidant additives were made by Tastrak (Bristol, U.K.) and evaluated by us with a Bevalac exposure at the University of California, Berkeley.
Y.D. He, P.B. Price
openaire   +1 more source

A new method for identification of ions in a CR-39 detector

Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1989
Abstract We have developed an identification method suitable for the identification of ions with E A > 10 MeV in CR-39 detector. The measurements have been done on the tracks of various ions with energies 10 E A MeV . We established the lengths of the etched tracks after two successive etching as the identification parameters ...
B. Grabež, P. Vater, R. Brandt
openaire   +1 more source

Home - About - Disclaimer - Privacy