Results 21 to 30 of about 3,692 (130)

Electrically Coded Retinomorphic Spectrophotodetector

open access: yesAdvanced Materials, EarlyView.
Self‐powered retinomorphic pyro‐photodetector is demonstrated that avoids machine‐learning post‐processing and covers 365–940 nm. Electrostatic balancing of built‐in potential produces an electrical wavelength code, delivering <3 nm wavelength decoding accuracy with ∼46 µs response.
Mohit Kumar, Hyunmin Dang, Hyungtak Seo
wiley   +1 more source

Constrained total least squares localization using angle of arrival and time difference of arrival measurements in the presence of synchronization clock bias and sensor position errors

open access: yesInternational Journal of Distributed Sensor Networks, 2019
Based on measurements of angle of arrival and time difference of arrival, a method is proposed to improve the accuracy of localization with imperfect sensors. A derivation of the Cramér–Rao lower bound and the root mean square error is presented aimed at
Ruirui Liu   +3 more
doaj   +1 more source

On stability of generalized phase retrieval and generalized affine phase retrieval

open access: yesJournal of Inequalities and Applications, 2019
In this paper, we consider the stability of intensity measurement mappings corresponding to generalized phase retrieval and generalized affine phase retrieval in the real case. First, we show the bi-Lipschitz property on measurements of noiseless signals.
Zhitao Zhuang
doaj   +1 more source

Terahertz Channel Modeling, Estimation and Localization in RIS‐Assisted Systems

open access: yesAdvanced Electronic Materials, EarlyView.
Reconfigurable intelligent surfaces have become a recent intensive research focus. Based on practical applications, channel strategies for RIS‐assisted terahertz wireless communication systems are categorized into three different types: channel modeling, channel estimation, and channel localization.
Hongjing Wang   +9 more
wiley   +1 more source

Self‐calibrated B1+ and B0 Field Inhomogeneities Estimation (SAFE) in 3D Magnetic Resonance Fingerprinting

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop SAFE, a self‐calibrated framework to estimate B1+ and B0 field inhomogeneities directly from conventional magnetic resonance fingerprinting (MRF) acquisitions and improve its quantification accuracy. Methods SAFE utilized a two‐step approach. First, two physics‐informed image markers are extracted from the MRF data to create
Mengze Gao   +13 more
wiley   +1 more source

Research on power allocation of integrated VLPC based on deep reinforcement learning

open access: yesTongxin xuebao, 2022
A power allocation scheme for integrated visible light position and communication (VLPC) system based on deep reinforcement learning was proposed to achieve power allocation for communication positioning integration.First, the frame structure design of ...
Shuai MA   +7 more
doaj   +2 more sources

Comparison of estimation limits for quantum two-parameter estimation

open access: yesPhysical Review Research
Measurement estimation bounds for local quantum multiparameter estimation, which provide lower bounds on possible measurement uncertainties, have so far been formulated in two ways: by extending the classical Cramér-Rao bound (e.g., the quantum Cramér ...
Simon K. Yung   +4 more
doaj   +1 more source

Analyzing of Cooperative Locating Error and Formation Configuration of AUV Based on Geometric Interpretation

open access: yesXibei Gongye Daxue Xuebao, 2020
Because the evaluation of the location performance of AUVs with the lower bound of the Cramer-Rao inequality is not intuitive, the geometric interpretation method is proposed based on geometric ellipse.

doaj   +1 more source

Effect of Signal-Dependent Shot Noise on Visible Light Positioning

open access: yesIEEE Photonics Journal, 2022
This paper investigates the error bounds for position estimation in downlink visible light communication (VLC) systems. More precisely, we use Cramér-Rao lower bounds (CRLBs) to study the effect of signal-dependent shot noise (SDSN) on the error ...
Ahmad Cheema, Malek Alsmadi, Salama Ikki
doaj   +1 more source

Improving Fetal Single‐Voxel Magnetic Resonance Spectroscopy With Spectral Registration

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate whether spectral registration improves spectral quality and quantification reliability in in vivo single‐voxel fetal brain MRS: Methods Fourteen fetal PRESS datasets were acquired at 3 T at TE = 35 ms and TE = 135 ms. Raw data were processed with eddy‐current phase correction, coil combination, spectral registration, and ...
Andres Saucedo   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy