Results 31 to 40 of about 6,560,224 (199)
The demand for internal nondestructive testing and inspection techniques is rapidly increasing. Using a continuous wave (CW) terahertz (THz) imaging system, we demonstrate that the internal defects in cross-linked polyethylene (XLPE) plates for power ...
In-Sung Lee, Joong Wook Lee
doaj +1 more source
To study the effect of antioxidant and graphite nanoplatelets ( GNPs) on the direct current ( DC) dielectric properties of cross-linked polyethylene ( XLPE ) ,antioxidant /XLPE and GNPs/antioxidant /XLPE composites were prepared by melt blending method ...
ZHANG Cheng-cheng +4 more
doaj +1 more source
DC cross-linked polyethylene (XLPE) power cables are being used recently for HV/EHV applications, the reliability of which is claimed to be significantly affected by space charge accumulation in the insulating material.
Zhipeng Lei +8 more
doaj +1 more source
Abstract Electrical trees are the degradation events most linked with partial discharge (PD) activity in cross-linked polyethylene (XLPE) insulation of high voltage (HV) cables. To investigate tree structures and forms, study of electrical tree structures for morphological analysis often carried out using optical microscopy.
M A M Isa +8 more
openaire +1 more source
Introduction. Power cables with cross-linked polyethylene (XLPE) insulation have significant advantages over traditional oil-filled ones, which have led to their widespread use in high-power electrical networks of all developed countries.
A. A. Shcherba +4 more
doaj +1 more source
Correlation Between Thermal Parameters and Morphology of Cross-Linked Polyethylene
This paper reveals a correlation between morphology and thermal parameters on cross-linked polyethylene (XLPE) cable with different insulating states. Several cables were selected to detect the physicochemical and thermal parameters of the XLPE.
Yifeng Zhao +9 more
doaj +1 more source
Algorithm for load cycling correction to minimise the dry zone influences on the cross‐linked polyethylene (XLPE) cable insulation [PDF]
Dry zone formation around underground power cables during load cycling may lead to thermal failure of the cable's insulation. This phenomenon has to be recorded to send an alarm to the maintenance crew when the soil around the cable reaches the critical value at which the dry zone has started to be formed.
Osama E. Gouda, Gomaa F.A. Osman
openaire +1 more source
Research and Development of 66 kV Water Tree Retardant XLPE Light Insulated Submarine Cable
This paper introduces the development method of a light submarine cable with rated voltage of 66 kV and water tree retardant cross linked polyethylene insulation(XLPE).
Guo CHEN +6 more
doaj +1 more source
<p>A partial discharge described as anon-linear electrical break-down even that happened in a section of insulating area between two conduct which are at different potentials the damage of the insulating material, these conductors have a different insulating material potential of damage, under AC voltage discharge interval process. In this paper,
Rasha Abdul-nafaa Mohammed +2 more
openaire +2 more sources
ABSTRACT The thermal state of underground power cables can be monitored based on the temperature dependency of the dielectric permittivity of the insulation material. The resulting temperature‐dependent wave velocity is used as a thermometric property. To this end, the signal propagation time along a cable of an injected signal is determined.
Peter Wouters +2 more
wiley +1 more source